background image

LED Display On/Off:

To set the LED display to turn off after 10 seconds, press the MODE 

button until ds-X is displayed, “X” representing either 1 or 2. Press 

the UP or DOWN button so that ds-2 is displayed, now the display 

will turn off after 10secs. Press any button for at least 5secs. to turn 

the display on again. Be advised though that the display will turn off 

automatically after 10 seconds of inactivity. 
ds-1= LCD display on at all times.

ds-2= LCD display shuts off after 10 seconds.

Operating Modes:

You can use the EPAR QA in four ways:

•  Macro Mode - There are 64 color macros to choose from.

•  Auto Mode - There are 9 built in programs to choose from.  

•  RGBA mode - Control the intensity of all four colors adjusting the    

  intensity to your desire.

•  DMX control mode - This function will allow you to control each

  individual fixtures traits with a standard DMX 512 controller such as

  as the Elation® Show Designer™.

Macro Mode:

1.   Plug the fixture in and press the MODE button until “C-XX” is dis-

    played. “XX” representing a number between 0-64.

2.   There are 64 macros to choose from. Select your desired macro by  

    pressing the UP and DOWN buttons. 

Program Mode:

1.   Plug the fixture in and press the MODE button until “A-XX” is dis-

    played. “XX” representing a number between 1-09 or AL.

2.   There are 9 built-in programs to choose from or you can select    

    “A-AL” and run all 9 programs. Select your desired program by 

    pressing the UP and DOWN buttons. You can set your program    

    speed by following the next set of instructions.

Program Mode Speed Adjustment:

1.   To adjust the speed of your program press the MODE button until  

    “P-XX” is displayed. 

2.   Press the UP or DOWN buttons to make the adjustmetns. “P-01” is  

    the slowest speed, “P-16” the fastest speed. When the display 

    reads “P-So” the Auto mode is running by sound activity. 

 EPAR QA                                          Operating Instructions

Elation Professional  -  www.elationlighting.com  - EPAR QA Instruction Manual Page 8

Elation Professional  -  www.elationlighting.com  - EPAR QA Instruction Manual Page 7

RGB Mode:

1.   Plug the fixture in and press the MODE button until: 

2.   When rXXX is displayed you are in Red dimming mode. Press the  

    UP and DOWN buttons to adjust intensity.

3.   When GXXX is displayed you are in Green dimming mode. Press the  

    UP and DOWN buttons to adjust intensity.

4.   When bXXX is displayed you are in Blue dimming mode. Press the  

    UP and DOWN buttons to adjust intensity.

5.   When AXXX is displayed you are in amber dimming mode. Press the  

    UP and DOWN buttons to adjust intensity.

6.   You can use the color macro chart on page 16 to create one of the 64  

   macros.

DMX Mode:

Operating through a DMX controller gives the user the freedom to create 

their own programs tailored to their own individual needs. The EPAR QA 

has 6 DMX modes: 1 Channel mode, 3 Channel mode, 5 Channel mode, 

6 Channel mode, 8 Channel mode, and a 9 Channel mode. See pages 

10-15 for each modes’ DMX traits.

1.  This function will allow you to control each individual fixture’s traits  

  with a standard DMX 512 controller such as the Elation®  Show   

  Designer™ or the Elation® DMX Operator™.

2.  To run your fixture in DMX mode, plug in the fixture via the XLR con-

  nections to any standard DMX controller. Select your desired DMX  

  mode, and then press the UP or DOWN buttons to adjust the DMX 

 address. 

XXX = DMX Address

3.   To run the 1 Channel Mode, press the MODE button until “1XXX”  

  is displayed. This is the DMX addressing for the 1 Channel Mode.

4.   To run the 3 Channel Mode, press the MODE button until “2XXX”  

  is displayed. This is the DMX addressing for the 3 Channel Mode.

5.   To run the 5 Channel Mode, press the MODE button until “3XXX”  

  is displayed. This is the DMX addressing for the 5 Channel Mode.

6.   To run the 6 Channel Mode, press the MODE button until “4XXX”  

  is displayed. This is the DMX addressing for the 6 Channel Mode.

7.   To run the 8 Channel Mode, press the MODE button until “5XXX”  

  is displayed. This is the DMX addressing for the 8 Channel Mode.

8.   To run the 9 Channel Mode, press the MODE button until “6XXX”  

  is displayed. This is the DMX addressing for the 9 Channel Mode.

9.   Please see pages 10-15 for DMX values and traits.

 EPAR QA                                          Operating Instructions

Содержание EPAR QA

Страница 1: ...ful DMX intelligent 4 in 1 RGBA Red Green Blue Amber LED wash This wash is light weight and compact which makes it a great piece for mobile DJ s and clubs This unit can be used as a stand alone or a sound active mode The unit can also be con trolled via DMX controller Customer Support Elation provides a customer support line to provide set up help and to answer any question should you encounter pr...

Страница 2: ... that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance EPAR QA Warranty Registration EPAR QA Features T...

Страница 3: ... sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Elation Professional www elationlighting com EPAR QA Instruction Manual Page 5 EPAR QA Set Up Elation Profes...

Страница 4: ...m EPAR QA Instruction Manual Page 7 RGB Mode 1 Plug the fixture in and press the MODE button until 2 When rXXX is displayed you are in Red dimming mode Press the UP and DOWN buttons to adjust intensity 3 When GXXX is displayed you are in Green dimming mode Press the UP and DOWN buttons to adjust intensity 4 When bXXX is displayed you are in Blue dimming mode Press the UP and DOWN buttons to adjust...

Страница 5: ...ard XLR data cables to link your units together Remem ber that the Male XLR connector is the input and the Female XLR connector is the ouput The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only 2 Set the Master unit to your desired mode or operation 3 For the Slave unit s set the display to any DMX channel mode Ex...

Страница 6: ...252 MACRO 63 253 255 MACRO 64 EPAR QA 5 Channel Mode DMX Values and Functions Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 5 DIMMER CURVE SETTING 0 20 DR 0 SETTING 21 40 DR 1 SETTING 41 60 DR 2 SETTING 61 80 DR 3 SETTING 81 100 DR 4 SETTING 101 255 DIMMER CURVE SETTING IS ACTIVE Channel 5 is the dimmer curve setting please see the Dimmer Curve...

Страница 7: ... PLEASE SEE 1 CHANNEL MODE 6 0 15 NOTHING 16 255 STROBING SPEED CONTROL 7 MASTER DIMMER 0 255 0 100 8 DIMMER CURVE SETTING 0 20 DR 0 SETTING 21 40 DR 1 SETTING 41 60 DR 2 SETTING 61 80 DR 3 SETTING 81 100 DR 4 SETTING 101 255 DIMMER CURVE SETTING IS ACTIVE Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 5 MASTER DIMMER 0 255 0 100 6 DIMMER CURVE ...

Страница 8: ...m 7 6 5 5 2 8 4 1 7 6 1 2 o r c a m 0 83 115 0 4 5 o r c a m 7 8 5 5 2 5 9 1 7 7 2 2 o r c a m 0 97 166 0 5 5 o r c a m 7 7 5 5 2 4 3 2 7 7 3 2 o r c a m 1 100 167 0 6 5 o r c a m 4 4 1 4 4 1 5 5 2 8 5 1 4 2 o r c a m 0 40 86 0 7 5 o r c a m 3 5 1 3 5 1 1 5 2 5 5 2 5 2 o r c a m 209 219 182 0 8 5 o r c a m 7 4 1 7 4 1 5 7 1 5 5 2 6 2 o r c a m 42 165 85 0 9 5 o r c a m 8 3 1 6 8 1 8 3 1 5 5 2 7 2 ...

Страница 9: ...nectors it does matter which way the inputs and outputs are connected Unit does not respond to sound 1 Quiet or high pitched sounds will not activate the unit Elation Professional www elationlighting com EPAR QA Instruction Manual Page 18 Elation Professional www elationlighting com EPAR QA Instruction Manual Page 17 EPAR QA Photometric Chart EPAR QA Photometric Beam Angle Data Standard 10 Beam An...

Страница 10: ...o liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the prod uct is modified in any manner which Elation Professionals concludes after inspec tion affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professiona...

Отзывы: