Elation Professional - www.elationlighting.com - ELED Par RGB Zoom - Page 10
Elation Professional - www.elationlighting.com - ELED Par RGB Zoom - Page 9
ELED Par RGB Zoom Operating Instructions
2. Use the UP or DOWN buttons to adjust the fade speed.
Seven Color Fade Mode: Note:
1. Plug the fixture in and press the MODE button until “F.XX” is dis-
played.
2. Use the UP or DOWN buttons to adjust the fade speed.
DMX Mode:
Operating through a DMX controller give
s the user the freedom to create
their own programs tailored to their own individual needs. The ELED Par
RGB Zoom has 6 DMX channels. See the chart below the DMX traits and
values.
1. This function will allow you to control each individual fixture’s traits
with a standard DMX 512 controller such as the
Elation® Show
Designer™ or the Elation®
DMX Operator
™.
2. To run your fixture in DMX mode, plug in the fixture via the XLR con-
nections to any standard DMX controller.
3. Press the UP or DOWN buttons to adjust the DMX address.
Channel Value
Function
1 RED
1 - 255 0% - 100%
2 GREEN
1 - 255 0% - 100%
3 BLUE
1 - 255 0% - 100%
4 MASTER DIMMER
1 - 255 0% - 100%
5 0 - 10 NOTHING
11 - 255 STROBING
6 ZOOM
1 - 255 10˚ - 60˚
ELED Par RGB Zoom DMX Values and Functions
ELED Par RGB Zoom Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter
-
nal optical lenses must be carried out periodically to optimize light
output.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Clean the external optics with glass cleaner and a soft cloth
every 20 days.
3. Always be sure to dry all parts completely before plugging
the unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (i.e. smoke, fog residue, dust, dew).
ELED Par RGB Zoom Trouble Shooting
Listed below are a few common problems the user may encounter,
with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are
wired correctly (pin 3 is “hot”; on some other DMX devices
pin 2 may be ‘hot’). Also, check that all cables are connected
to the right connectors; it does matter which way the inputs
and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
The fuse holder is located at the rear of the unit above the power
cord. Disconnect from the main power supply. Insert a standard flat
head screw driver in to the fuse holder housing, turn the screwdriver
in counter-clockwise direction to remove the fuse holder. Remove the
old fuse and discard it, replace the fuse with the same type. Insert the
fuse back into it’s housing.
ELED Par RGB Zoom Fuse Replacement