4 channel hybrid pack with dual Edison sockets per channel.
All four channels are user assignable between Dimmer & Switch
modes.
Device can functions as a one, two or four channel pack.
16 built in chase programs with speed and intensity settings.
Power failure memory..
4 digit digital LED-display.
0-100% dimming capability.
Four 10A fuses. One per channel, AC120V, 5x20mm
4 channel LED’s indicate relevant channel activity.
Troubleshooting
Troubleshooting
Fuse Replacement
10
No Power to the pack:
No Channel output:
Undesired 100% channel switch output:
Disconnect the main power line cord. Reconnect the line cord to
ensure proper connection. If the problem still persists, check the building
service panel and make sure the circuit breakers are on.
Disconnect the main power line cord. Check the corresponding channel
fuse (see replacing fuses section). Replace if blown. Reconnect line cord.
If controlling via DMX, ensure that you are receiving DMX signal at the
pack. Indicator in the display should be flashing when signal is present. If
signal is not present, check the XLR connections from console or previous
fixture in line. If problem still persists, replace XLR cable between previous
device and pack and try again.
Check the “Dim/Switch” settings. Ensure all channels are set to dim. If problem
still persists, ensure that you are not receiving channel output from your
console by disconnecting the XLR input cable from the pack.
If you’ve tried the above and the unit continues to malfunction, please contact
ELATION customer service at (323) 582-3322, your unit will require service.
Once you describe your problem to the customer service representative, you
will be issued a return authorization number that must accompany the package
when sent in. Please write this RA# on the outside of the box with a black
marker and also write it on any packing list that may be included with the
package.
External Fuse Replacement: Disconnect the main power line cord.
Internal Fuse Replacement: Disconnect the main power line cord.
Use a flat head screwdriver to remove the fuse holder cap. Pull out the old fuse
and replace it with a new one of the exact same type. Replace the fuse cap with
the flat head screw driver. Do not over tighten as this may result in a broken and
unusable fuse holder.
Remove the six phillips head screws from the rear panel. Locate fuse on circuit
board, remove and replace with exact same type. Replace rear panel and six
screws.