Design Spot 1400E™
©Elation Professional® 54 Design Spot 1400E™
17. ERROR CODES:
When power is applied, the unit will automatically enter a “reset/test” mode. This mode
brings all the internal motors to a home position. If there is an internal problem with one or
more of the motors an error code will flash in the display in the form of “XXer” were as XX will
represent a function number. For example, when the display shows “02Er,” it means there is
some type of error with the channel 2 motor. If there are multiple errors during the start-up
process they will all flash in the display. For example: if the fixtures has errors on channel 1,
channel 2, and channel 5 all at the same time, you will see the error message “01Er”, “02Er,”
and ”05Er” flash repeated 5 times.
If an error does occur during the initial start-up procedure the fixture will self-generate a
second reset signal and try to realign all the motors and correct the errors, if the error persist
after a second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the fixture will make the
following determinations: 1) 3 or more errors - The fixture cannot function properly with three
or more errors therefore the fixture will place itself in a stand-by mode until subsequent
repairs can be made. 2) Less than 3 errors - The fixture has less than 3 errors, therefore
most other functions will work properly. The fixture will attempt to operate normally until the
errors can be correct by a technician. The errors in question will remain flashing in the
display as a reminder of internal errors.
Pan Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The PAN-
movement is not
located in the default position after the reset.
Tilt Er
(TILT-head movement error) This message will appear after the reset of the fixture if the
head’s magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The TILT-
movement is not
Содержание Design Spot 1400E
Страница 1: ...Rev 08 28 2008 visage Design Spot 1400E Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 ...
Страница 58: ...Design Spot 1400E Elation Professional 58 Design Spot 1400E in the default position after the reset ...
Страница 62: ...Design Spot 1400E Elation Professional 62 Design Spot 1400E 20 PHOTOMETRIC DATA ...
Страница 63: ...Design Spot 1400E Elation Professional 63 Design Spot 1400E 21 DIMENSIONAL DRAWINGS ...
Страница 64: ...Design Spot 1400E Elation Professional 64 Design Spot 1400E 22 CIRCUIT SCHEMATIC ...
Страница 65: ...Design Spot 1400E Elation Professional 65 Design Spot 1400E ...