background image

Power Spot 575™ 

©Elation Professionals®   Los Angeles, Ca.     -     wwww.ElationLighting.com      -        Page 

18 

 

3.1 Setting/Changing  the DMX Address  

After applying power to the 

POWER  SPOT  575™ 

the LED will display the fixture’s 

current  DMX  address  immediately  after  the  reset  sequence.  If  the  fixture  is  not 
receiving a DMX signal the display will flash continuously. 

D001

 

 

To set or adjust a DMX address, please follow the procedure below: 

1.  Switch  on  the 

POWER  SPOT  575™ 

and  wait  for  the  fixture  reset  process  to 

finished (

'

RESE

'

 will flash in the LED while fixture is in reset mode).  

2.  Press  the 

Mode 

button  to access  the main menu.  Toggle  through  the  menu  by 

pressing the 

Up 

and

  Down 

buttons until the display shows 

D001

. Tap the enter 

button  to  make  changes  to  the  address,  the  current  three  digit  address  will 
immediately begin to flash. 

3.  While the current three-digit address is flashing, use the 

Up 

and

 Down 

buttons

 

to 

select  adjust  the  address.  Lock  your  new  address  into  the  unit’s  memory  by 
pressing  the 

Enter 

button.  After  the  new  address  has  been  successfully  stored 

into the fixture’s memory the LED will briefly readout 

OK

.  

The  DMX  address  is  non-destructible  and  will  remain  in  the  fixture’s  memory  even 
when  the  power  has  been  switched  off.  Memory  is  backed-up  and  retained  by  an 
internal power source with a five year shelf life. 

3.2 Test Program  

Test

 

 

The 

Test 

Program  engages  the  fixture’s  internal  test  mode.  This  function  runs  a 

complete  test  procedure  of  all  functions.  Press 

Enter

  to  launch  the  self-test  or  the 

Mode

 button to cancel and return to the main menu. 

3.3  The Audio Program  

Audi

 

 

The 

Audio 

menu allows you to run a stand-alone audio program. This program can 

run  either  fast  (

AFST

)  or  slow  (

Aslw

);  Fast  (

AFST

):  When  running  in  “fast”  mode 

every sound impulse will trigger a new step. (

Aslw

): When running in You may run 

Содержание Color Spot 575

Страница 1: ...User Manual Software Version 1 60 Revised 06 2004...

Страница 2: ...Power Spot 575 Elation Professionals Los Angeles Ca wwww ElationLighting com Page 2...

Страница 3: ...ower Spot 575 12 2 3 Connections 13 2 3 1 Power Supply 13 2 3 2 DMX 512 Pin Configuration 13 2 4 DMX 512 13 2 5 Data Cable Requirements 13 2 6 Special Note 13 2 7 Line Termination 13 2 8 MX Pin Conver...

Страница 4: ...rections EFLD 25 3 10 Error and Information Messages 25 4 Operating Modes 27 4 1 Universal DMX Control 27 4 2 Stand Alone Sound Active 27 4 3 Master Slave 28 5 DMX Channel Selection DMX Protocol 29 6...

Страница 5: ...unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer withou...

Страница 6: ...ol Remember lamps are not covered under warranty conditions This fixture emits intense UV radiation which is harmful to the eyes and skin The intense luminance of the lamp can cause severe damage to t...

Страница 7: ...cooled 5 Never look directly into the lamp beam You risk injury to your retina which may induce blindness 6 Be sure to track and record the lamp running time The lamp should be changed at the end of...

Страница 8: ...Button 10 Mode Button 11 Firmware Connection 12 Microphone Sensitivity 13 DMX Input Jack 14 DMX Output Jack 15 Power On Off Switch 16 Fuse Housing 3 15 A Max Min DMX IN DMX OUT Software Update 1 G ro...

Страница 9: ...e cooling process This fan is designed to vary its velocity at different operating temperatures to provide better cooling when the fixture reached higher operating temperatures associated with long us...

Страница 10: ...nal 14 DMX Output Jack This jack is used to transmit the incoming DMX signal to another DMX fixture or transmit a Master Slave signal to the next Power Wash 250 in the chain For best results in DMX or...

Страница 11: ...ty cable that can hold at least 10 times the weight of the fixture Never use the carrying handles for secondary attachment Refer to regulations BGV C1 formerly VBG 70 and DIN VDE 0711 217 for proper i...

Страница 12: ...he cam locks to the designated position on the bottom of your unit Lock the cam locks into position by turning the wing nuts 90 90 b Be sure to always use two cam locks mounted to the bottom of unit t...

Страница 13: ...communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fixture DMX data is sent out as serial data that travels from fixture...

Страница 14: ...le XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and can not be split 2 6Notice Be sure to follow the above figure when making your own cables Do not use...

Страница 15: ...system is protected by a 5x20 mm external fuse 250v 10A US model or 230V T 5 A EU model The fuse requirements are clearly printed on the side of the fixture WARNING Always disconnect main power befor...

Страница 16: ...o program slow AFST Self running audio program fast MSTR Master for the audio program SVPT Basic position for the audio program SIZE Size for the audio program NORM BIG MIDL SMAL LAMP Switch on of the...

Страница 17: ...after reset clre Settings in the internal memory technician only facc Must read on Protected with a code VTIL Software version tilt pc board VTOP Software version top pc board VBOT Software version bo...

Страница 18: ...o flash 3 While the current three digit address is flashing use the Up and Down buttons to select adjust the address Lock your new address into the unit s memory by pressing the Enter button After the...

Страница 19: ...chain as the master All others must be Slave Master OFF Notice The Audio function is only working if no DMX is connected 3 4 Lamp On Off LAMP This function allows you to manually control the lamp oper...

Страница 20: ...8 Invert Tilt Movement RTLT This function allows you to invert all tilt movements Use the Up and Down buttons to turn this function On and Off Press the Enter button to accept the change or the Mode b...

Страница 21: ...X 255 DIMR 000 255 Dimmer FOCU 000 255 Focus SPEC 000 255 Lamp Off Reset LASR 000 255 Laser 3 9 2 Lamp On automatic lamp strike LAAU This function automatically strikes lamp when main power is turned...

Страница 22: ...55 Gobo rotation GOB2 000 255 Gobo wheel 2 PRIS 000 255 Prism wheel SHUT 000 255 Shutter Strobe function DIMR 000 255 Dimmer FOCU 000 255 Focus SPEC 000 255 Lamp Off Reset MOVE 000 255 Movement SPED 0...

Страница 23: ...ing then press Enter to accept your setting or press the Mode button to cancel and return to the menu The chart below will detail the different fan settings HIGH The cooling fan works continuously at...

Страница 24: ...tment of the Color wheel GOB1 99 99 Adjustment of the Gobo wheel 1 GOB2 99 99 Adjustment of the Gobo wheel 2 PRIS 99 99 Adjustment of the Prism wheel SHTR 99 99 Adjustment of the Shutter POFS 99 99 Ad...

Страница 25: ...ggle between ON and OFF and confirm once more with the Enter button or use the Mode button to cancel the operation 3 9 11 Error and Fault Corrections EFLG These functions are reserved for authorized t...

Страница 26: ...off the lamp Pleas look for possible reasons fan faulty air in outlets blocked or very dirty lamp broken or very old too high ambient temperature Switch off the power supply and solve the possible pro...

Страница 27: ...DMX traits A DMX controller allows you to create unique programs tailored to your individual needs The Power Spot 575 uses 16 DMX channels See page 27 for detailed description of the DMX traits To con...

Страница 28: ...of a sound source tapping on the fixture or high pitched sound may not trigger the fixture 4 3 Master Slave Operation Sound Active This function will allow you to link up to 16 fixtures together and o...

Страница 29: ...0 color 5 color 6 fast 22 23 16 17 8 8 color 6 Orange fast 24 25 18 19 9 6 color 6 color 7 fast 26 27 1A 1B 10 4 color 7 Canary fast 28 29 1C 1D 11 2 color 7 color 8 fast 30 31 1E 1F 12 0 color 8 Ita...

Страница 30: ...4 fast 24 31 18 1F 9 11 9 Gobo 5 fast 32 39 20 27 12 14 9 Gobo 6 fast 40 47 28 2F 15 17 9 Gobo 7 fast 48 55 30 37 18 20 9 Gobo 8 fast 56 63 38 3F 21 23 Gobo 1 open slow 64 71 40 47 24 26 9 Gobo 2 slow...

Страница 31: ...ion 255 FF 100 9 Shutter Shutter closed 0 15 00 0F 0 6 Random Strobe different pattern 16 31 10 1F 7 11 9 Strobe Pulse effect slow fast min frequent 0 7 Hz 32 47 20 2F 12 12 9 Strobe effect slow fast...

Страница 32: ...29 1C 1D 11 2 4 270 30 31 1E 1F 12 TILT size phase see also PAN 32 63 20 3F 13 25 PAN TILT size phase see also PAN 64 95 40 5F 26 37 PAN TILT inverse size phase see also PAN 96 127 60 7F 38 50 Circle...

Страница 33: ...xture Don t touch the bulb of the lamp with bare fingers this can cause damages Before you put the POWER SPOT 575 into operation close the casing otherwise your retina can be hurt 6 2 Lamp Change 6 2...

Страница 34: ...from your skin may damage the lamp Always replace with the lamp with a lamp that meets the orginal lamp specification failure to do so may damage the unit and will void your manufactures warranty 6 2...

Страница 35: ...inue to blow fuses STOP using the fixture Contact customer support for further instructions you may have to return the unit for servicing Continuing to use the unit may cause serious damage Fuse Repla...

Страница 36: ...n 8 1Installing Replacing Gobos 8 1 1 Always be sure to disconnect the main power supply before attempting any service 8 1 2 Remove the upper shell of the protective cover by removing the 4 retaining...

Страница 37: ...Professionals Los Angeles Ca wwww ElationLighting com Page 37 Special Notice Wheel with rotating Gobos Wheel with non rotating Gobos If you use glass gobos the non vaporized side must be fitted towar...

Страница 38: ...edures 9 1 Safety Regulations Always disconnect main power before attempting any service related issues Allow ample time for the lamp to cool at least 20 minutes before performing any cleaning procedu...

Страница 39: ...changed at the first sign of ware usually in about 1 2 years lens will begin to look cloudy For lens replacement please contact Elation technical support 9 3 Cleaning the Optical System recommended f...

Страница 40: ...utside diameter 27 mm image size 23 mm All gobos as steel or glass Gobos exchangeable 9 spare Gobos Shutter Strobe Dimmer Strobe effect with variable speed 1 10 flashes per second Continuously mechani...

Страница 41: ...ge to any such accessories or for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professionals...

Страница 42: ...ssed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacem...

Страница 43: ...Power Spot 575 Elation Professionals Los Angeles Ca wwww ElationLighting com Page 43 12 Dimensions...

Страница 44: ...X 9 DMX Address 11 DMX Protocol 19 E Error Messages 18 F Feedback 17 Fixture Temperature 15 Fuse 9 G Glass Gobos 24 I Injury of the retina 6 M Maintenance 25 Measures 27 Mounting 7 Mounting plate 7 P...

Страница 45: ...ly into the beam and the beam from striking the audience DANGER VISIBLE LASER RADIATION VISIBLE LASER RADIATION VISIBLE LASER RADIA AVOID DIRECT AVOID DIRECT A EYE EXPOSURE VOID DIRECT EYE EXPOSURE VO...

Страница 46: ...Power Spot 575 Elation Professionals Los Angeles Ca wwww ElationLighting com Page 46...

Страница 47: ...Power Spot 575 Elation Professional 4295 Charter Street Los Angeles CA 90058 323 582 3322 323 582 3108 fax www ElationLighting com info ElationLighitng com...

Отзывы: