Note 1:
add a safety rope attached the light's base insurance shelf, do not connect
the device handle.
Note 2: Lights be placed vertically upward, the shortest distance between working
lights must be more than or equal 500mm, lighting installation layout as follow.
5.3 Data cable
Data cable is DMX512 signal.
Caution: Signal line connections is X-type connector.
X-type connector-----If the external flexible cable or cord of this light is damaged, please replace
professional cable or cord from the manufacture or its agent.
Lights’ DMX input and output connects to a 3&5pin XLR, first pin is grounded, then negative signal is
second pin, third pin connects to the positive polarity signal, the fourth and fifth is empty.
In order to prevent reception reflection and interference control signal, a terminal plug must be installed
on the first branch of the connected device last 3-pin output jack.