9.1 Protection against removal from mounting surface
Compliance with EN 50131 regulation grade 2 requires that the device is protected against removal from the mounting
surface.
Install KSAS1013 kit (green) before fixing the detector base to the fixture.
A
- open pre-drilled area A
- cut the cable connector off
- feed the cable (from the free end) in the drilled hole
-
1 cm
fix a S4 dowel (supplied) to the wall at a height of 1 cm from the hole
- fix the eyelet to the dowel
- fix the detector base to the fixture
- connect the wires to the 24H terminals on board