background image

© 2017 EL-CELL GmbH 

   User Manual 

Release 1.0 

PAT-Chamber-16 / PAT-Chamber-16 C 

Temperature-controlled docking station 

Содержание PAT-Chamber-16 C

Страница 1: ...2017 EL CELL GmbH User Manual Release 1 0 PAT Chamber 16 PAT Chamber 16 C Temperature controlled docking station...

Страница 2: ...cies EL CELL GmbH maintains the right to make changes without further notice to products described in this manual to improve reliability function or design EL CELL GmbH does not assume any liability a...

Страница 3: ...escription 4 2 Safety instructions 5 3 Technical data 6 4 Installation 8 5 Operation 10 6 EC Link software 12 7 Cleaning 12 8 Unpacking 12 10 EC declaration of conformity 13 11 Technical support 16 12...

Страница 4: ...Cell Press The PAT Cell the PAT Core and the EC Link data logger software are covered in detail by other manuals http el cell com downloads downloads manuals PAT Chamber 16 and PAT Chamber 16 C with...

Страница 5: ...ries Don t place other goods inside the chamber 2 1 Localization position of safety labels on the PAT Chamber 16 The following lables are located on the unit Electrical hazard After removing covers li...

Страница 6: ...PAT Chamber 16 3 Technical data Dimensions 635 mm width x 378 mm depth x 374 mm height Dimensions with attached PAT Connect 16 C 635 mm width x 378 mm depth x 449 mm height Temperature 10 to 80 C Wei...

Страница 7: ...meplate provides information about the appliance model manufacturer and technical data It is attached to the back of the appliance 1 2 5 3 6 Type designation Operating voltage Connection power ratings...

Страница 8: ...ess than 25 cm Sufficient air circulation in the vicinity of the instrument must be guaranteed at all times 4 1 Connection to the external battery tester or potentiostat Two versions of the PAT Chambe...

Страница 9: ...rument will immediately power up once connected Note that the cells docked into the PAT Chamber 16 will experience self discharge across a resistance of approx 10 kOhm between WE and CE in case the in...

Страница 10: ...the corresponding cell socket is free LED off or occupied LED lit In order to change the setpoint temperature press the select button then adjust the displayed setpoint with the arrow buttons and con...

Страница 11: ...e the lid 5 2 Workflow This section gives a quick overview on how to run a test with a PAT Cell docked into the PAT Chamber and connected to an external battery tester More details on the EC Link soft...

Страница 12: ...emicals for cleaning Protect the PAT Chamber 16 from dust and splash water 8 Unpacking Check the contents of the packages against the list given below to verify that you have received all of the requi...

Страница 13: ...Page 13 of 16 Release 1 0 User Manual PAT Chamber 16 10 EC declaration of conformity...

Страница 14: ...uipment for measurement control and laboratory use Part 2 201 Particular requirements for control equipment IEC 61010 2 201 2013 EN 61010 2 010 2015 05 Sicherheitsbestimmungen f r elektrische Mess Ste...

Страница 15: ...equipment for measurement control and laboratory use EMC requirements Part 2 3 Particular requirements Test configuration operational conditions and performance criteria for transducers with integrate...

Страница 16: ...ited Warranty does not cover defects damage or nonconformity resulting from abuse misuse neglect lack of reasonable care modification or the attachment of improper devices to the goods This Limited Wa...

Страница 17: ...2017 EL CELL GmbH User Manual Release 1 0 PAT Connect 16 Adapter box for flexible wiring connections...

Страница 18: ...cies EL CELL GmbH maintains the right to make changes without further notice to products described in this manual to improve reliability function or design EL CELL GmbH does not assume any liability a...

Страница 19: ...Page 3 of 10 Release 1 0 User Manual PAT Connect 16 Content 1 Product description 4 2 Technical data 5 3 Installation 6 4 Cleaning 8 5 Unpacking 9 6 Accessories 9 7 Technical support 10 8 Warranty 10...

Страница 20: ...temperature pressure and buffered half cell voltages and makes these signals available to the external battery tester Two different versions of the PAT Connect 16 are available The PAT Connect 16 for...

Страница 21: ...5 of 10 Release 1 0 User Manual PAT Connect 16 2 Technical data Dimensions PAT Connect 16 334 mm width x 195 mm depth x 106 mm height Dimensions PAT Connect 16 C 350 mm width x 177 mm depth x 75 mm he...

Страница 22: ...PAT Connect box comes always readily connected upon delivery The connection cables between docking station and connect box are available in different lengths PAT Connect 16 Cable Set 10 10 700 mm leng...

Страница 23: ...ween 3 and 5 may differ between battery testers The leads WE CE and RE are always present albeit possibly with other names 1 Full cell control 2 Half cell control 1 vs R lower half cell Battery tester...

Страница 24: ...use aggressive chemicals for cleaning Protect the device from dust and moisture Battery tester potentiostat WE CE RE WE Sense CE Sense PAT Connect 16 2 1 R 2S 1S 3 3 Cable colors and naming convention...

Страница 25: ...ELL if anything is missing or damaged NOTE Damaged shipments must remain within the original packaging for freight company inspection List of components PAT Connect 16 ECE1 00 0130 A or PAT Connect 16...

Страница 26: ...ted Warranty does not cover defects damage or nonconformity resulting from abuse misuse neglect lack of reasonable care modification or the attachment of improper devices to the goods This Limited War...

Страница 27: ...2017 EL CELL GmbH Quick Guide EC Link Software Release 2 5 Using with PAT Tray PAT Stand 16 PAT Chamber 16...

Страница 28: ...med for inaccuracies EL CELL GmbH maintains the right to make changes without further notice to products described in this manual to improve reliability function or design EL CELL GmbH does not assume...

Страница 29: ...6 PAT Chamber 16 Release 2 5 Content 1 What is EC Link 4 2 EC Link System Requirements 4 3 Installing the EC Link Software 4 4 Running the EC Link Software 5 5 Log files 8 6 Settings 10 7 Post Process...

Страница 30: ...s cycle wise integrated and differential capacity data and stores them in separate result files Connection between the PC host and the data logger is being established via USB Multiple instruments and...

Страница 31: ...cell is inserted the corresponding channels are displayed as zero Data recording can be started for an inserted test cell only The insertion and recording status of all cell positions is given in the...

Страница 32: ...half cells such as Graphite vs Lithium This parameter is required to distinguish between cycles threshold current refers to the absolute value of the current considered as zero This parameter is requ...

Страница 33: ...ill affect the data of all inserted cells in the presently displayed time window 7 Click the View file button in the headline to view the log file data of the selected channel in text format 8 Double...

Страница 34: ...n m Cycle t_cycle s time of given cycle P mW power Qtot mAh charge obtained by integration of current over time Qcd mAh same as Qtot but nulled at start of each half cycle Qcd mAh absolute value of Qc...

Страница 35: ...2 Delta Q Delta V12 mAh V C1R txt contains the differential capacitance data of the positive half cell Format Columns Cycle Time s t_cycle s V1R V Delta V1R V Delta Q mAh C1R Delta Q Delta V1R mAh V C...

Страница 36: ...gorithm The Reduction Algo max Error E has a great impact on the efficiency of the data reduction and hence on the size of the compressed _Small txt log file In short the algorithm checks if a given d...

Страница 37: ...new processing parameters Note that this function can only be applied on the original uncompressed txt log files The Post Process dialog prompts for the maximum error of the reduced data written into...

Страница 38: ...ftware Run setup exe and overwrite the existing directory C Program Files EC Link When upgrading the EC Link software from a version below 2 0 we recommend the following procedure Download and unzip t...