background image

Model: WS-1517                                               www.lacrossetechnology.com/support                                                        1 

 

 
 
 

 

Professional Wireless Weather Station 

 
La Crosse Technology

®

, the world leader in atomic time and weather instruments, introduces a Professional Wireless 

Weather Station that provides accurate, real-time weather data straight from your backyard. This sleek weather station 
offers weather forecasting, indoor/outdoor temperature & humidity, wind & rain data, and precise atomic time & date—all 
on one comprehensive device. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Model:

 WS-1517U 

Instruction Manual 

DC:

 120314 

Содержание WS-1517U

Страница 1: ...ther instruments introduces a Professional Wireless Weather Station that provides accurate real time weather data straight from your backyard This sleek weather station offers weather forecasting indoor outdoor temperature humidity wind rain data and precise atomic time date all on one comprehensive device Model WS 1517U Instruction Manual DC 120314 ...

Страница 2: ...Contents 2 Features 3 Setup Instructions Step by Step 3 LCD Screen 6 Buttons 6 Program Menu 6 Language 6 City Code Time Zone 6 Set Calendar 7 Set Time 7 Custom Settings 7 Clock and Alarm Window 7 WWVB Radio Controlled Time Signal 8 Manual Signal Search 8 Time Alarm 8 Alarm Snooze Set 8 Activate Deactivate Alarm 9 Snooze Function 9 Pressure and Weather Window 9 Pressure and Altitude Information 9 L...

Страница 3: ...metric Pressure Barometric Pressure with 24 hr history graph Local Barometric Pressure reading 12 24 hr atomic time and date with manual set option Outdoor temperature F C Outdoor humidity RH Indoor temperature F C Indoor humidity RH Wind chill F only Wind speed mph m s km h knots Wind direction compass display Rainfall amount inches mm Time alarm with snooze weekly and single day settings Calenda...

Страница 4: ...the wind cups are securely mounted on the anemometer shaft and spin freely Battery installation 1 Remove four 4 screws from the battery compartment of the wind sensor Be careful not to drop them 2 Open the battery compartment and install two 2 AA size Alkaline batteries not included matching the polarities shown 3 Replace the battery compartment door and secure the screws STEP 3 Thermo hygro 1 Sli...

Страница 5: ...5 15 minutes During this time the weather station will flash the pressure and weather icon and InHg inches of mercury Setup is completed when the weather station shows default settings for pressure and altitude sea level indoor outdoor temperature and humidity wind and rain readings etc InHg STEP 6 Set Wind Direction 1 Wait until all the sensor readings are received by the weather station 2 Manual...

Страница 6: ... this weather station The TS21 thermo hygro sensor does not read to other channels Program Menu The SET button will move through the program menu The UP or DOWN arrow buttons will change a value Language 1 Press the UP or DOWN arrow button until the clock and alarm icon flashes ENG 2 Hold SET button until the day of week language abbreviation ENG will flash 3 Press the UP or DOWN arrow button to s...

Страница 7: ...P or DOWN button to select either 12 hour AM PM or 24 hour time 24 00 format Press the SET button to confirm selection and move to the hour 2 The hour will flash Press the UP or DOWN button to select the correct hour Press the SET button to confirm selection and move to the minutes 3 The minutes will flash Press the UP or DOWN button to select the correct minute Press the SET button to confirm sel...

Страница 8: ... weather station is programmed to search for the atomic time signal daily each hour between 1 00 am and 4 30 am Once the time signal has been successfully received the time and date will be updated automatically Manual Signal Search With the clock and alarm icon flashing hold the UP arrow for three seconds to manually search for the WWVB signal A triangular tower icon will start flashing next to t...

Страница 9: ...altitude work together Set either the sea level pressure or the local altitude but not both Press and release the SET button to alternate between Sea Level Pressure Local Pressure Local Altitude settings Local Pressure reflects pressure changes at your specific location house The local altitude elevation must be programmed according to GPS readings internet etc Sea Level Pressure reflects pressure...

Страница 10: ... bar graph shows barometric pressure variations over the past 24 hours This is very useful for understanding the Barometric trends that are used in weather forecasting Each bar icon represents 0 06 InHg Alternatively the bar chart can be used to display 24 hour trend data for sea level pressure outdoor temperature or outdoor humidity channel 1 only 1 Select the Pressure and Weather Forecast window...

Страница 11: ...approximate alignment with the moon and the sun on opposite sides of the earth The illuminated portion of the moon faces the earth giving us complete visibility of one side of the entire moon After a full moon the illuminated portion will decrease or wane until the new moon occurs First Quarter and Last Quarter moons occur when the moon is at a 90 degree angle to the earth and sun We see half of t...

Страница 12: ...shows the connection status of the remote sensor When there is no signal the remote sensor reading will show dashes Search for Remote Sensors Hold the DOWN arrow button for 4 6 seconds to activate a search for all remote sensors Normally the weather station will automatically find and display measurement results from the remote sensors Occasionally other radio transmission sources TV cordless or c...

Страница 13: ...ess and release the UP or DOWN buttons until the alarm reads OFF 3 When the temperature shows with the high or low alarm icon the alarm is active 4 When the temperature shows without the alarm icon the temperature alarm is off High temperature alarm active Low temperature alarm active High and low alarm active MAX MIN Records View With the temperature and humidity icon flashing press the MEMORY bu...

Страница 14: ...nized as midnight Sunday to midnight Saturday MONTHLY RAIN Monthly rain reflects the previous month s rain and will update 12AM the first day of the month Select Rain Display inches or mm With the rain icon flashing hold the SET button to toggle rainfall units of measure mm or inches 24 Hour Rainfall Alert Set Daily Rainfall Alert 1 With the rain icon flashing press ALARM CHART button to display t...

Страница 15: ...ots With the wind icon flashing hold the SET button to set the wind speed units in km h kilometers per hour mph miles per hour m s meters per second knots Wind MAX MIN The weather station records the maximum wind speed and wind gusts collected during the day Alerts for wind speed and wind gust may be programmed View With the wind icon flashing press and release the MEMORY button to view Current av...

Страница 16: ... 5 Wait at least 10 seconds and then reinsert the A C adapter and batteries IMPORTANT Do not press any buttons during the setup process which take 5 15 minutes During this time the weather station will flash the pressure icon and InHg inches of mercury Setup is completed when the weather station shows default settings for pressure and altitude sea level indoor outdoor temperature and humidity wind...

Страница 17: ...ects can reduce the range by one half Place sensors and weather station in desired locations and wait approximately 30 minutes before permanently mounting to ensure that there is proper reception Wind For most accurate wind readings mount the wind sensor as the highest item in the area with a 50 foot clearance in all directions avoid tall trees buildings or other obstructions that may block or ref...

Страница 18: ...nditions While the thermo hygro sensor is weather resistant avoid submersion in water or snow We recommend that you mount the outdoor temperature sensor on an outside North facing wall The remote thermo hygro sensor can stand vertically on a flat surface or mounted on the wall in vertical position Use screws when mounting the thermo hygro sensor on the wall Avoid placing the thermo hygro sensor ne...

Страница 19: ...ling Interval 10 seconds Transmitting Interval around 47 seconds Operating range 100 feet 30 m open air Wind Direction Range 0 to 360 Resolution 22 5 Transmitting interval 33 seconds Operating Range 100 feet 30 m open air Wind Speed Range 0 to 199 9mph 199 9 Km h 173 7 Knots 89 3 m s Resolution 0 1mph 0 16 Km h Starting Threshold 3mph 4 8 Km h Wind Gust Speed Update Interval 33 seconds Wind Gust S...

Страница 20: ...gy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct ...

Страница 21: ...X 6 DAL Bremen Germany 1 BRE Nairobi Kenya 3 NBO Houston TX 6 Hou Brussels Germany 1 BRU Nanjing Nanking China 8 NKG Memphis TN 6 MEM Buenos Aires Argentina 3 BUA Odessa Ukraine 2 ODS Mexico City Mexico 6 MEX Budapest Hungary 1 BUD Omaha Nebraska USA 6 OMA Milwaukee WI 6 MKE Cairo Egypt 2 CAI Oslo Norway 1 OSL Minneapolis MN 6 MSP Caracas Venezuela 4 CCS Paris France 1 PAR New Orleans LA 6 MSY Cal...

Отзывы: