Step 5. 

Please use 12 pieces of M2,5×6mm screws to install FB block as shown on picture 3.

 

              

 

 

Picture 3:

 Installing the block.

 

 

Step 6. 

Tighten all M2,5 screws equally and gradually to prevent the chipset cores from breaking, especially if 

not  using  standoffs.  Please  be  very  careful  while  screwing  over  Mosfet  area  if  you  are  not  using  Acetal 
standoffs. 

 

Step 7. 

Remove the block and check for contact surface. Then repeat steps 3 to 6. And apply more or less 

pressure on area where you have found it necessary. 

 

Step 8

. Connect the water-block(s) to your water cooling system and attach the tubes. Any fitting can be used 

as an inlet or outlet. To ensure the tubes stays properly on the fittings please use hose clamps or appropriate 
substitute. The use of an algaecide is nonetheless recommended in any liquid cooling system. 

 

Step 9

. Users who wish to replace top level 2 (bridge) can find enclosed red acrylic transparent top in the box. 

While  replacing  it,  please  be  very  careful  not  to  use  too  much  force  when  screwing  -  acrylic  is  prone  to 
cracking, and damaging the threads in the top level 1 is very likely if using too much force on the screws. Also 

make sure washer is well placed in the groove (channel).  
HINT:  When  washer  flattens  equally  all  around  and  sits  nicely  in  groove  that  is  indicator  that  is  being  well 
placed. 

 

VERY IMPORTANT NOTICE 

Once  the  installation  is  completed,  it  is  always  a  good  idea  to  test  the  circuit  for  leaks,  prior  to  powering  up  the  computer.  We 

recommend a 24 hour leak test prior to powering up the computer. Do not test the water block directly from city water pressure. 
This will bow the top of the housing and render the block unusable (and will void your warranty).

 

IMPORTANT DISCLOSURES: 

While  all  efforts  have  been  made  to  provide  the  most  comprehensive  tutorial  possible,  EK  Water  Blocks  assumes  no  liability 

expressed or implied for any damage(s) occurring to your components as a result of using EK Water Blocks cooling products, either 

due to mistake or omission on our part in the above instructions, or due to failure or defect in the EK Water Blocks cooling products. 

WARRANTY: 

Our products are guaranteed for 24 months from the date of delivery to the final user against defects in materials or workmanship. 
During this period, they will be repaired or have parts replaced provided that: (I) the product is returned to the agent from which it 

was purchased; (II) the product has been purchased by the end user and not used for hire purposes; (III) the product has not been 
misused, handled carelessly, or other than in accordance with any instructions provided with respect to its use. This guarantee does 

not confer rights other than those expressly set out  above and does not cover any claims for consequential loss or damage. This 
guarantee is offered as an extra benefit and does not affect your statutory rights as a consumer. 

The guarantee is not valid if 

there are used aggressive UV additives. 

 
ADDITIONAL NOTICE:

  

USE OF STANDOFFS IS OBLIGATORY. FURTHERMORE , PLEASE DO NOT USE TO MUCH TIGHTENING FORCE ON THE 2 SCREWS AROUND SOUTHBRIDGE.ONLY IN THIS WAY 

THE  POTENTIAL DAMAGE TO YOUR MOTHERBOARD IS  AVOIDED. 

This notice is written upon the letter from EVGA RMA department. They state they will deny all RMA's if they find improper mounting method was used.

 

 
 