STEP 4:  CONNECTING YOU RESERVOIR 

 

Connect  two  G1/4  threaded  fittings  to  the  reservoir  (IN)  and  pump  (OUT).  Please  note  the  water  flow  orientation.  EKWB recommends  using  EK-PSC 

fittings with the EK-BAY DCP 2.2 Combo Reservoir series reservoirs. To ensure that the tubes are securely attached to the barb/fittings, please use hose clamps 

or an appropriate substitute. 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

STEP 5: FILL RESERVOIR                                              

 
 

Fill  reservoir  through  G3/8  threaded  fill  port  (marked  with  arrow)  and  make  sure  liquid  is  not  spilled  over  your  computer  or  any  electrical  devices  nearby. 

Preferably, your pump's height level should be lower than that of the EK-BAY RES Single reservoir in order to flood and prime the water pump. Run your pump 

shortly  for  couple  of  times  to  make  sure  water  floods  your  tubes  and  other  water  cooling  components.  Repeat  the  procedure  until  you  are  done  and  pay 
attention to the water level in your reservoir. Lowest and highest recommendable water levels are indicated on the reservoir's front panel (

min

max

). Once done 

with the filling process please close your EK-BAY DCP 2.2 Combo Reservoir with G3/8 plug and tighten the seal using enclosed Allen key. 

 

STEP 5:  OTHER INSTRUCTIONS  

VERY IMPORTANT NOTICE: 

Once the installation is completed, it is a recommended practice to test the cooling circuit for leaks prior to powering up the computer. We recommend a 24 hour leak test prior to powering 

up the computer. Do not test the water block using tap water pressure. This will rupture the top of the housing and render the block unusable (and will void your warranty).While all efforts have been made to provide the 
most comprehensive tutorial possible, EK Water Blocks assumes no liability expressed or implied for any consequential damage(s) occurring to your equipment as a result of using EK Water Blocks cooling products, either 
due to errors or omissions on our part in the  above instructions, or due to failure or defect in the EK Water Blocks cooling products. 

WARRANTY:

Our products are warranted against defects in materials or workmanship for a period of 24 months beginning from the date of delivery to the final user. During this period, products will be repaired or have 

parts replaced at our discretion provided that: (I) the product is returned to the agent from whom it was purchased; (II) the product has been purchased by an end user and has not used for commercial purposes;  (III) the 
product has not been misused, handled carelessly, or used in a manner other than in accordance  with the instructions provided describing its installation and proper use. This warranty does not confer rights other than 
those expressly set out above and does not cover any claims for consequential loss or damage.  This warranty is offered as an extra benefit and does not affect your statutory rights as a consumer. This warranty is voided if 
the product comes in contact with aggressive UV additives or other improper liquids. 

 

REQUIRED TOOLS: 

philips head screwdriver

 

 

 

Water out 

(to radiator or water block)

 

Inlet G1/4 
threaded port 

EK PSC fitting 

Water in 

(from radiator or water block)

 

Tubing 

Predrilled holes for 5mm LEDs 
(acrylic  version only) 

EK-DCP 2.2 
Water Pump 