28
www.irsun.eu
EN
Installation Procedure
The regulator must be installed on a wall in the standard flush-mounted
socket (Ø 68 mm), minimum 35 mm deep. The socket must be installed on
the wall before the regulator is installed. The regulator must be installed at
eye level on the inner wall which is not exposed to the direct sunlight. It also
must be far away from other objects that could create additional warmth,
since they could affect the measuring of the room temperature.
1.
Turn off the fuse to which the regulator will be connected.
2.
Remove the screw from the flush-mounted socket.
3.
Take the back part of the regulator and connect it
as shown on the next page of this manual.
4.
Safely attach the power supply part of the
regulator to the flush-mounted socket.
5.
Take the display part of the controller and carefully
place it on the power supply part of the regulator.
During installation do not touch the touch screen.
6.
Turn on the fuse to which the regulator is connected.
Warning:
Attention, high voltage! Before starting the installation,
disconnect power. Installation should be carried out by a person with
appropriate qualifications.