![EKOS EKOSync 1588A Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ekos/ekosync-1588a/ekosync-1588a_user-manual_2374273006.webp)
5
EKOSync 1588A User Manual rev 1.1
August 2021
Timing accuracy: ≤50 ns to UTC
Networking:
GENERAL
DHCP:
Auto-configuration with fall back to ARP
tested link-local address
VLAN:
Packet tagging
PTP (IEEE 1588 V2)
General:
One-step or two-step operation
End-to-end or peer-to-peer delay calculations
Layer 2 (Ethernet) or Layer 3 (UDP) transport
Slave only mode
Default Profile support
Power Profile support:
C37.238
TLV support:
C37.238 offset from TAI time base used by PTP
Alternate Time Offset TLV support: with automatic or manual offset
NTP
General:
Stratum-1 NTP & SNTP time server
Multicast & Broadcast server capability
Optional MD5 authentication
Environmental Specifications:
Operating and Storage conditions
Operating Temperature
-20° to 60°C (-4 to 140°F) according to
UL 60950
-20° to 70°C (-4 to 158°F) according to
IEC 60065
Storage Temperature
-20° to 70°C (-4 to 158°F)
Operating Ambient Humidity 3% to 97% (non-condensing conditions)
Altitude
3000m (9842 ft)
Mechanical Specifications:
Dimensions (H x W x D)
44 x 439 x 247,5 mm
Weight
3.920 kg
Antenna Port Specifications:
Voltage
3.3 VDC
Current
100 mA (max)