MAINTENANCE
NP-DK50 DS-23_08-2018
19
Replacing the inlet filter (21)
•
Unlock the cover and pull it out.
•
Replace the filter
•
Lock the cover
Spare part:
Intake filter 05W POLYESTER, Item 025200194-000
Stabilizing the compressor before shipping
Before shipping, the compressor must
be stabilized to prevent movement.
Prior to fixation, it is necessary to
disassemble the plastic cover. The air
pump must be fixed to the base using
the four original M6 screws (see
picture). Assemble the plastic cover.
SHUT-DOWN
If the compressor is not going to be used for a long period of time,
disconnected it from the main power supply and release the pressure in the
air tank.
EQUIPMENT DISPOSAL
•
Disconnect the equipment from the main power supply.
•
Release the pressure in the air tank.
•
Dispose of the equipment according to local regulations.
•
Parts used in this product have no negative impact on the environment
when disposed of properly.
BATTERY DISPOSAL
No battery may be disposed with common household waste. Dispose of
non-functional batteries at suitable collection sites.