MAINTENANCE
NP-DK50 DS-23_08-2018
17
•
Only allow the safety valve freely
puff
for a short period of time
.
Never use the safety valve to release pressure in the air tank. This could
damage the safety valve.
Check tightness of joints and inspect the equipment
Test for leakage:
•
Disconnect the outlet hose from the quick coupling OUT (9); compressed
air consumption will stop.
•
Pressurize the air tank by releasing some air via a connected device.
•
With the compressor off, wait at least 10 minutes before checking the
pressure level.
•
If the pressure has dropped, use soapy water to find the leaky joint. Start
with the joints outside the case, and then test the ones inside the case
after removing the covers.
•
Tighten or re-seal joints as necessary.
Inspect the equipment:
•
Check the status of the compressor motor for balanced operation or noise.
•
Check the condition of the hangers above the pump.
•
Check fan functionality.
•
Check the condition of the filter. With regular operation, condensate from
the filter (19) drains automatically. Verify this function by comparing the
level of condensate in the bottle to the scale line indicating the maximum
level. If the level of condensate is above the scale line, replace the faulty
parts.
•
Examine the pump for:
- Defects in the crankcase
- Free movement of the crank shaft
•
If necessary, replace any faulty parts.
Replacing filters elements
Before beginning, evacuate all compressed air from the tank, reducing
the tank pressure to zero and disconnect the equipment from the power
mains.