TROUBLESHOOTING
02/2020
47
NP-DK50 PLUS, 2V-A-3_02-2020-MD
TROUBLESHOOTING
Risk of electric shock.
Before any of the following operations on the device, disconnect the device from
the mains (pull out the mains plug).
Risk of injury during work with pneumatic components under pressure.
Before any of the following operations on the device, it is necessary to decrease
pressure in the air tank and in the pneumatic system to zero.
Any operations concerning the troubleshooting may be performed only by
a qualified technician.
Malfunction
Possible cause
Solution
Compressor does
not switch on
No voltage in the pressure switch
Check voltage in socket
Check circuit breaker switch
–
switch to position switched-
on „I“
Loose conductor from terminal -
repair
Check electrical cord
– replace
defective cord
Motor winding failure, damaged
thermal protection
Replace motor or windings
Capacitor failure
Replace capacitor
Seized piston or other rotating part
Replace damaged components
Pressure switch does not switch
Check function of pressure switch
Cabinet switch
does not switch off
the compressor
There is a compressor in the cabinet
that previously worked separately
(there is a jumper in the compressor
terminal strip)
Remove the jumper from the
terminal strip, see. Chap. 0
Compressor often
switches on
Air leakage in pneumatic system
Check pneumatic system
– seal
loose connections
Non-return valve (SV) leakage
Clean non-return valve, replace
seals, replace non-return valve
Large volume of condensed liquid in
pressure tank
Drain condensed liquid
Low compressor capacity
Check time of filling the air tank
Low pressure in
the air tank
(compressor
running constantly)
High air consumption of supplied
equipment
Decrease air consumption
Use compressor with higher
capacity
Leakage in pneumatic system
Check pneumatic system
– seal
loose connections
Low capacity of the pump
Clean / replace the pump
Pump failure
Clean / replace the pump
Dryer failure
Replace dryer
Prolonged
operation of the
Air leakage in pneumatic system
Check pneumatic system
– seal
loose connection
Содержание DK50 2V S
Страница 1: ...DK50 PLUS M DK50 2V M User manual Benutzerhandbuch N vod na pou itie...
Страница 2: ......
Страница 4: ...CONTENTS 5 INHALT 49 OBSAH 94...
Страница 14: ...PRODUCT DESCRIPTION NP DK50 PLUS 2V A 3_02 2020 MD 14 02 2020 Fig 2 DK50 2V M Compressor with dryer...
Страница 15: ...PRODUCT DESCRIPTION 02 2020 15 NP DK50 PLUS 2V A 3_02 2020 MD Fig 3 Cabinet...
Страница 25: ...INSTALLATION 02 2020 25 NP DK50 PLUS 2V A 3_02 2020 MD Fig 6 Changing door direction...
Страница 44: ...PRODUCT MAINTENANCE NP DK50 PLUS 2V A 3_02 2020 MD 44 02 2020 Fig 21 230V A B...
Страница 58: ...PRODUKTBESCHREIBUNG NP DK50 PLUS 2V A 3_02 2020 MD 58 02 2020 Abb 2 DK50 2V M Kompressor mit Trockner...
Страница 59: ...PRODUKTBESCHREIBUNG 02 2020 59 NP DK50 PLUS 2V A 3_02 2020 MD Abb 3 Kompressorgeh use...
Страница 69: ...INSTALLATION 02 2020 69 NP DK50 PLUS 2V A 3_02 2020 MD Abb 6 ndern der T r ffnungsrichtung...
Страница 89: ...PRODUKTWARTUNG 02 2020 89 NP DK50 PLUS 2V A 3_02 2020 MD Abb 21 230V A B...
Страница 103: ...POPIS V ROBKU 02 2020 103 NP DK50 PLUS 2V A 3_02 2020 MD Obr 2 DK50 2V M Kompresor so su i om MD...
Страница 104: ...POPIS V ROBKU NP DK50 PLUS 2V A 3_02 2020 MD 104 02 2020 Obr 3 Skrinka...
Страница 114: ...IN TAL CIA NP DK50 PLUS 2V A 3_02 2020 MD 114 02 2020 Obr 6 Zmena otv rania dver...
Страница 133: ...DR BA V ROBKU 02 2020 133 NP DK50 PLUS 2V A 3_02 2020 MD Obr 21 230V A B...
Страница 141: ......
Страница 142: ......
Страница 143: ......