background image

DK50  

 

             

SM-DK50-EN-1-08-2014-MD

 

  

     08/2014 

 

 

       

For version without dryer  

                                                                         

For version with dryer

 

Air pump

 230/50     1BA-509             601011511

-000

        

Air pump

  230/50           1BA-507             601011507

-000

    

Air pump

 230/60      

Air pump

 230/60                                              

Air pump

 115/60                 

Air pump

 115/60                                               

 

Motor 230V/50-60Hz  1LF7096-4AJ97-ZN52 

035110008-000 

16 

Sealing liner   

4KB-892 

074000065-000 

1a  Capacitor 230V/50-60Hz     30 MF 

031330003-000 

17 

Bearing 

6304   

021000026-000 

Motor 110V/60Hz    1LF7096-4AJ97-ZN53 

035110015-000 

18 

Crank    

4CA-195   

604021195-000 

1a  Capacitor   110V/60Hz          2x60 MF 

031330010-000 

19 

Screw  

M8x16 

041000051-000 

Screw        

M6x110 

041000045-000 

20 

Crank case 

3KB-834 

050000033-000 

Washer  

6   

043000007-000 

21 

Side left    

3KB-912 

062000346-000 

Cylinder head complete    

 

 

22 

Motor holder    

3KC-417 

023000776-000 

4a   Compressor  with      dryer  4CA-247   

604021247-000 

23 

Screw  

M8x25 

041000511-000 

4b   Compressor  without dryer  4CA-208   

604021208-000 

24 

Washer   

8.IV   

043000009-000 

Spring 

 

022000010-000 

25 

Nut 

M8   

042000006-000 

O - ring 

d50x2 

073000109-000 

26 

Membrane  screw   

4KA-016.1    

024000007-000 

Valve plate 

4CA-023    

604021023-000 

27 

Membrane   

4KA-031.1    

024000008-000 

Cylinder   

4KB-832 

050000036-000 

28 

Piston ring el.    

 

069000123-000 

Piston with piston rod     

4CA-194 

604021194-000 

29 

Screw  

 

041000036-000 

10  Side right   

3KB-911   

062000345-000 

30 

Washer   

 

043000005-000 

11  Screw  

M6x25 

041000115-000 

31 

Membrane seat 

3KA-015   

024000006-000 

12 Screw 

 

M4x10 

041000110-000  32  Fitting 

 

G3/8MM 

025400119-000 

13  Crank case cap   

4KB-835 

050000034-000 

33 

Fitting 

G3/8MM 

025400119-000 

14 Filter 

element 

03 

025200126-000 

34 

Retaining ring 

 

024001920-000 

15  Suction plug 

3KB-893   

074000064-000 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Notice

       

-  

Bonded joints – adhesive

 LOCTITE 620 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4b 

4a 

Содержание DK50 2V/110

Страница 1: ......

Страница 2: ......

Страница 3: ...N 2 1 ALERT NOTICES AND SYMBOLS 2 2 MODEL VARIATIONS AND THEIR USES 3 3 TECHNICAL DATA 3 4 FUNCTION 4 INSTALLATION 6 5 WIRING DIAGRAMS 7 6 SWITCHING THE COMPRESSOR ON 8 MAINTENANCE 8 7 MAINTENANCE SCHEDULE 8 8 MAINTENANCE 8 9 SOLVING PROBLEMS 11 LIST OF SPARE PARTS 2 ...

Страница 4: ...n Dangerous electric voltage Read the user manual CE mark of compliance Caution Hot surface Compressor is remote controlled and may start without warning Earth ground connection Terminal for ground connection Fuse Alternating current Handling mark on package Fragile handle with care Handling mark on package This way up vertical position of cargo Handling mark on package Protect against moisture Ha...

Страница 5: ...over pressure 5 bar Lit min 1 75 75 75 75 Maximal current A 3 4 4 3 8 6 3 4 4 3 8 6 3 4 4 3 8 6 3 4 4 3 8 6 Maximal current of compressor with dryer A 3 6 4 5 8 8 3 6 4 5 8 8 Motor performance kW 0 55 0 55 0 55 0 55 Air tank capacity Lit 5 5 10 10 Pressure range bar 4 5 6 0 4 5 6 0 4 5 6 0 4 5 6 0 Maximum operating pressure of safety valve bar 8 0 8 0 8 0 8 0 Sound level LpfA dB 65 45 65 45 Mode o...

Страница 6: ... The dryer provides continuous drying of the compressed air Dry clean compressed air free from oil traces is stored in the air tank ready for use Compressor with condensation and filtration unit Fig 3 The compressor 1 draws in air through a filter 8 and compresses it through a check valve 3 into an air tank 2 The compressed air from the nozzle flows through a cooler 10 that cools the compressed ai...

Страница 7: ...mpressor motor 2 Air tank 3 Check valve 4 Pressure switch 5 Safety valve 6 Manometer 7 Drain valve 8 Input filter 9 Dryer 10 Pipe cooler 11 Output filter 12 Condenser outlet 13 Solenoid valve 14 Cooler 15 Check valve 16 Magnetic bottle holder 17 Fan 18 Micro filter 19 Filter 20 Bottle 21 Stopper 15 ...

Страница 8: ...n and training of all operators shall be confirmed by the installer s signature on the certificate of installation Prior to installation ensure that the compressor is free of all transport packaging and stabilizers to avoid any risk of damage to the product Caution When in operation the compressor is hot Burns or fire may result if contact is made by the operator or any flammable material 4 1 Plac...

Страница 9: ...he output pressure hose drain hose and power cord out the back of the compressor Slide the box over the compressor so that the front face of the box matches the front part of the compressor and the box is fully seated Make sure that the pressure hose drain hose and electric cord come out via the opening at the back of the box Position the drain hose with its valve in the holder at the rear of the ...

Страница 10: ...icable national legal regulations A report must be prepared on the results of the tests e g according to EN 62353 Annex G including the measurement methods used Time interval Maintenance that must be performed Chapter Performed by 1 x day Release condensate At high air humidity Compressor without air drier Compressors with air drier Compressors with condensation unit from filter from pressure vess...

Страница 11: ...nning the following procedures 8 2 Safety valve check Fig 5 When the compressor is operated for the first time make sure that the safety valve is working properly Turn screw 4 of safety valve 1 several rotations to the left until the safety valve releases air Let the safety valve blow out for only a few seconds Turn screw 4 to the right until it seats closing the valve The safety valve must never ...

Страница 12: ... disconnect the appliance from the mains Fig 10 In the case of a regular operation of a condensation unit it is necessary to replace the filter inside the filter with automatic desludging Release a safety lock 1 on the filter vessel by its pulling downwards slightly rotate the filter cover 2 to the left and take it out Unscrew the filter holder 3 by its rotation to the left Replace the filter and ...

Страница 13: ...eater volume of condensed liquid in pressure vessel Check pneumatic distribution system seal loose joint Clean valve replace seals replace valve Drain condensed liquid Prolonged running of compressor Air leak in pneumatic distribution system Worn piston ring Contaminated input filter Defective solenoid valve Check pneumatic distribution system seal loose joint Replace worn piston ring Replace cont...

Страница 14: ...er 5 3 043000002 000 3 Rubber leg 074000004 000 3 Rubber leg 074000004 000 4 Noise insulatation pad 4KA 134 061000018 000 4 Noise insulatation pad 4KA 532 061000037 000 5 Noise insulatation pad 4KA 136 061000056 000 5 Noise insulatation pad 4KA 534 061000059 000 6 Lower case 2KA 133 023000259 000 6 Lower case 2KA 343 023000258 000 7 Rivet 044000012 000 7 Rivet 044000012 000 8 Noise insulatation pa...

Страница 15: ...x5 061000260 000 17 Noise insulatation pad 41 x11 5x3 061000259 000 6 Lower case compl 023001704 000 18 Noise insulatation pad 41 5x3x2 061000254 000 7 Pin 049000154 000 19 Noise insulatation pad 061000258 000 8 Pin spring M4 049000155 000 20 Noise insulatation pad 4KC 256 062000411 000 9 Nut M4 042000002 000 21 Fan tunnel 4KC 143 023000652 000 10 Washer 4 043000003 000 22 Rivet 044000012 000 11 N...

Страница 16: ... 024000238 000 21 Nut M8 042000006 000 3 Electric panel 230 50 604021059 000 22 Safety valve 4BA 025 604011025 000 115 60 604021152 000 23 Gasket CU 4KA 078 025900003 000 4 Thermo switch 033510012 000 24 Manometer 50 G 025400003 000 5 Fuse T10A 230 50 60Hz 038100005 000 25 Silencer G 1 8 025400018 000 T 16A 110 50 60Hz 038100007 000 26 Solenoid valve 230 50 036100022 000 6 Electric board housing 6...

Страница 17: ...400003 000 6 Fuse T10A 230 50 60Hz 038100005 000 25 Solenoid valve 230 50 036100022 000 T 16A 110 50 60Hz 038100007 000 115 60 036100045 000 7 Electric board housing 604031537 000 26 Silencer 025400018 000 8 Screw D3 2 041000004 000 27 Input hose 4BA 013 604011013 000 9 Fixing lug 033400034 000 28 Dryer 603012169 000 10 Fixing lug 033400018 000 11 Damping element S 4CA 215 604021215 000 12 Screw M...

Страница 18: ...r 3KC 417 023000776 000 4a Compressor with dryer 4CA 247 604021247 000 23 Screw M8x25 041000511 000 4b Compressor without dryer 4CA 208 604021208 000 24 Washer 8 IV 043000009 000 5 Spring 022000010 000 25 Nut M8 042000006 000 6 O ring d50x2 073000109 000 26 Membrane screw 4KA 016 1 024000007 000 7 Valve plate 4CA 023 604021023 000 27 Membrane 4KA 031 1 024000008 000 8 Cylinder 4KB 832 050000036 00...

Страница 19: ...switch pipe 024000357 000 2 Plug 4KA 953 024000247 000 12 Securing Nut 024000162 000 3 Base plate 5l 3KB 954 023000567 000 13 Non return valve 025300007 000 Base plate 10l 3KB 909 023000534 000 14 Fitting MF3 8 025400034 000 4 Rubber leg 074000010 000 15 Fitting 1 4 024000311 000 5 Washer 5 3 043000101 000 6 Screw M5x25 041000208 000 7 Pressure switch 604031061 000 8 Nut 024000027 000 9 Gasket CU ...

Страница 20: ...000208 000 12 Plug 4KA 953 024000247 000 4 Fitting block to press switch 024000101 000 13 Plug 024000844 000 5 Gasket CU 025900004 000 14 Non return valve 025300007 000 6 Nut 024000027 000 15 Fast on coupling 025500247 000 7 Pressure switch pipe 024000357 000 16 Base plate 10l 3KC 116 023000640 000 8 Securing Nut 024000162 000 9 Pressure switch 604031061 000 Notice Bonded joints adhesive LOCTITE 2...

Отзывы: