INSTALLATION
04/2022
31
NP-DK50-9x4VRTM-AD-EN-5_04-2022
Fig. 23: Connecting the power cord
Description of air pump controls
The air pumps are controlled in sets of three
based on real demand. One of the three is
always set as the MASTER (e.g. M1-3) and
the
others
as
SLAVE1
(e.g.
M4-6)
and SLAVE2 (e.g. M7-9). The Slave sets
operate under the following conditions (see
Fig. 24):
-
A waiting period (pressurising to the
upper limit) of 1 minute under strong
demand and 2 minutes under weak
demand;
-
The activation pressures are below
6.4 bar (SLAVE1) and then below 6.2
bar (SLAVE2);
-
Motor failure in the MASTER section.
The lower limit settings ROTATE every 50
hours to ensure all the air pumps are evenly
loaded.
Fig. 24: Air pump controls
A
– motors M1-M3
B
– motors M4-M6
C
– motors M7-M9
UL
– upper limit
BL
– bootom limit → Master=6.4, SLAVE1=6.2, SLAVE2=6.0
Содержание 447000001-066
Страница 1: ...DK50 9x4VRT M User manual...
Страница 2: ......
Страница 13: ...PRODUCT DESCRIPTION 04 2022 13 NP DK50 9x4VRTM AD EN 5_04 2022 Fig 2 Electrical box switchboard...
Страница 15: ...TECHNICAL DATA 04 2022 15 NP DK50 9x4VRTM AD EN 5_04 2022 Dependence of compressor output on working pressure...
Страница 20: ...INSTALLATION NP DK50 9x4VRTM AD EN 5_04 2022 20 04 2022 Fig 5 Levelling the compressor Fig 6 Frame installation...
Страница 35: ...INSTALLATION 04 2022 35 NP DK50 9x4VRTM AD EN 5_04 2022 15 PNEUMATIC DIAGRAMS DK50 9x4VRT M DK50 9x4VRTS M...
Страница 66: ...ANNEX NP DK50 9x4VRTM AD EN 5_04 2022 66 04 2022 ANNEX 22 MAPPING PARAMETERS...
Страница 67: ...ANNEX 04 2022 67 NP DK50 9x4VRTM AD EN 5_04 2022...
Страница 69: ......
Страница 70: ......
Страница 71: ......