EKO INSTRUMENTS CO., LTD. Ventilation Unit MV-01 Instruction Manual V2
Pg. 14
5-3. Ventilator Tachometer
1. Tachometer Signal
The tach output can be monitored and conveys rpm information in the form of a square wave (2 block pulses
per revolution). The frequency of this square wave output is proportional to the rotation of the shaft. The tacho
signal can be measured using a frequency meter or pulse counter (12VDC / Pulse signal ~100Hz /
~3,000rpm).
*Fixed resistance of 2
kΩ
shown on the above figure is not provided and need to be prepared by customer.
(F
ixed resistance more than 2kΩ can be measured.)
1/2
Rotation
100.0 Hz
2
kΩ
Frequency
Meter
Fan Power Supply
12.0 Vdc
Figure 5-4. Tachometer Signal
Tel.: +11 3976-4003 • 3999-7737
vendas@romiotto.com.br
www.romiotto.com.br