5
Warning!
Incorrect disposal of this product may
cause serious damage to the environment and hu-
man health. Please be informed about the correct
disposal procedures for waste collecting and pro-
cessing provided by local authorities.
!
Local commands
Available functions:
N.O. pushbutton with memory / N.O. pushbutton without memory.
Light dimming by following the selected regulation
curve and by keeping the color temperature constant.
Soft start with 200ms fade time. Soft switch-off with
a fade time of 1s.
•
Click: Switch ON / OFF
•
Double Click: max. intensity (100%)
•
Long press (>1s) while OFF: switch ON at 1%
(Night function)
•
Long press (>1s) while ON: Dimming UP /
DOWN
Available functions: 0-10V / 1-10V / potentiometer.
Light dimming by following the selected regulation
curve and by keeping the color temperature constant.
Min. intensity = 0,1%
•
< 1 V: load OFF
•
10 V: max. intensity
Dimensions [mm]
108
91.00
36
62
108
91.00
36
62
Marks
• CE: the device complies with the Electromagnetic
Compatibility Directive (2014/30/EU) and the RoHS 2
Directive (2011/65/UE).
• Reference Standards: EN
61347-1:2008+A1:2011+A2:2013, EN 61000:2014-
3.2, EN 61000:2013-3.3, EN 62384:2006+A1:2009,
EN 55015:2013+A1:2015 , EN 61547:2009, EN
50581:2012
Maintenance
The device is maintenance-free. To clean use a dry cloth.
It must be avoided the use of solvents or other aggressive
substances.
Disposal
At the end of its useful life the product
described in this datasheet is classified
as waste from electronic equipment in
accordance with the European Directive
2012/19/EU (WEEE recast), and cannot
be disposed together with the municipal
undifferentiated solid waste.
Warnings
•
Installation, electrical connection, configuration and
commissioning of the device can only be carried out by
qualified personnel in compliance with the applicable
technical standards and laws of the respective countri-
es
• Opening the housing of the device causes the imme-
diate end of the warranty period
• In case of tampering, the compliance with the essential
requirements of the applicable directives, for which the