4
The use of an electric starter is recommended. A simple switch can be insufficient to start and
stop the electric motor connected to the main electric system.
An appropriate starter:
• Can prevent accidental starting after a failed attempt to start.
• Is a safe switch, protected against water.
• Protects the electric motor against overloads due to a short circuit (a fuse protects only the
wires).
• Resists against starting in overload on the motor, preventing dangerous electric arc and early
wear of the electrical contacts.
If the pump is kept in the warehouse make sure that it’s placed in a dry and protected
position; always use the original package or an equivalent protection. If the pump has to
remain stored for a long period and/or in particularly damp places the use of hygroscopic
substance (silica gel) is recommended to prevent damages.
Don’t remove the protections of the flanges until the installation and close, if they are not
closed already, the discharge and suction pump connections to prevent the intrusion of
foreign bodies.
Be informed that a long period of storage of the pumps can provoke:
Deterioration of the isolation of the motor due to absorption of dampness
Deterioration of the gaskets
2.2 Receipt and Inspection
Even if Ekin Endüstriyel takes all the necessary precautions during the packaging, we suggest
that you carefully check the received material.
Check the data on the label of the received pump and compare it with those relative to your
purchase order.
If the pump has been supplied with the motor, remove the protective shield from the fan of the
motor and try to rotate the motor shaft by hand. If you feel a strong resistance to rotation or if
you hear anomalous noises call the Ekin Endüstriyel assistance service directly. Reassemble the
protective fan shield before starting the pump.
2.3 Storage
Содержание GemmeCotti HTM 10 PP