The pump contains particularly powerful magnets. It’s forbidden for those who have 

cardiac pacemakers, defibrillators, electronic medical devices, metallic heart valves, 

metallic prosthesis or sickle cell anaemia, to handle or be in the proximity of the 

magnets contained inside the pumps. Consult a health care provider for specific 

recommendations before working with these pumps.

The powerful magnetic fields in the proximity of the pumps can damage heart 

pacemakers, watches, credit cards, discs and magnetic tapes inside calculators and 

computers.

When working in the proximity of pumps, consider that the devices or metallic parts that 

you are handling can be unexpectedly attracted towards the pump causing possible 

crushing of fingers or hands.

These pumps have been designed and manufactured to be used in specific conditions 

and within defined limits. The use outside these specifications has to be agreed and 

approved by the Ekin Endüstriyel technical service. It must be considered also that, 

if the pumps are used outside their technical specifications, the CE Certifications and 

the warranty are no longer valid. Furthermore, if the pump is used outside the technical 

specifications communicated to us at the moment of the quotation and confirmed in 

our order confirmation, the customer becomes responsible for the issue of a new CE 

Certification.

The pump has to be used only for the applications specified in the order for which 

GemmeCotti has selected the model, the materials of construction and has tested the 

pump to respect the specifications. For other uses different from those stated in the 

order, customer has to call the Ekin Endüstriyel technical office.

There will not be any warranty for repairs or alterations on the product done by the 

users or third parties not specifically authorized by Ekin Endüstriyel. Always shut down 

the pump before touching or proceeding with any intervention on it or on the circuit 

of installation. The pump must be empty of pumped liquid and it must be completely 

decontaminated and successfully rinsed with water before any manual operations or 

disassembling.

Make sure that the electrical system to which the pump will be connected has the 

adequate power and has the correct protection devices (e.g. grounding, life safe). 

Always switch off the electrical supply before working on the pump for maintenance or 

part substitution. Always keep an extinguisher next to the pump installed.

Always pay maximum attention in the execution of maintenance activities on pumps and 

on the connected circuits when they are used with dangerous liquids.

Содержание GemmeCotti HTM 10 PP

Страница 1: ...GemmeCotti User Guide...

Страница 2: ...www twitter com ekinendustriyel www facebook com ekinendustriyel www youtube com ekinendustriyel www linkedin com company ekinendustriyel www instagram com ekinendustriyel Follow us on social media...

Страница 3: ...n to engineering problems in the world market and have grown through an expansion of franchises Engineering Approaches Integrated Solutions Ekin has expanded into the production of components sales an...

Страница 4: ...ks Air Tubes Steel IBC Tanks with ADR Heat Stations Steam Package Systems Special Designed Systems Dosing Systems Substations Thermoregulators Lobe Pumps Hygienic Centrifuge Pumps Turbo Roots Centrifu...

Страница 5: ...1 Introduction 1 2 Installation 2 3 Operation 8 4 Maintenance 12 5 Problem Solutions 18 6 Spare Parts 18 7 Data 19 CONTENTS...

Страница 6: ...correct functioning and prevention of possible damage to the equipment This symbol indicates the presence of strong magnetic fields which can damage or compromise the functioning of other equipment n...

Страница 7: ...e remind you that the classification of the zone Ref Atex 2014 34 EU former 94 9 CE directive for potentially explosive atmoshpere zones have to be done by the customer and communicated to GemmeCotti...

Страница 8: ...municated to us at the moment of the quotation and confirmed in our order confirmation the customer becomes responsible for the issue of a new CE Certification The pump has to be used only for the app...

Страница 9: ...ended to prevent damages Don t remove the protections of the flanges until the installation and close if they are not closed already the discharge and suction pump connections to prevent the intrusion...

Страница 10: ...air siphon that can be created in the long piping line Avoid the creation of siphon also before the suction of the pump It is better to rinse the internal pipes of new plants before installing the pum...

Страница 11: ...or the same hazardous zone as the pump installed unless it s protected by an airtight closure cabinet also certified The installation of pumps type EM C T P for use in potentially explosive areas has...

Страница 12: ...motor correspond to those of the electric system to be used Don t connect the electric motor directly to the main system but protect the dedicated system with a suitable main switch with adequate saf...

Страница 13: ...ion strainer to avoid obstruction of the suction causing cavitation Avoid in particular to pumping liquids containing ferro oxides or other ferromagnetic particles even if small Read the following ins...

Страница 14: ...execution Do not allow the pump to run dry Note the mag drive pump design doesn tallow the dry running functioning because it will damage irrevocably the inner parts of the pump An accidental failure...

Страница 15: ...that the pump is installed in accordance with the instructions supplied in the previous section 2 3 5 Starting Start the electric motor and gradually open the discharge pipe until you reach the requi...

Страница 16: ...proofing canopy for the pump In these cases make sure that the motor ventilation is guaranteed 3 7 Shut Down Normally the pump should be shut down only after closing the discharge valve If the suction...

Страница 17: ...he warranty period extraordinary maintenance is allowed only for GemmeCotti personnel or personnel authorized by GemmeCotti All the operations described in the paragraphs below have to be done exclusi...

Страница 18: ...ssible that the pump has pumped toxic and or dangerous liquids so it s necessary to wear protection for the skin and the eyes Make sure that the pump has been carefully decontaminated and cleaned Wash...

Страница 19: ...TM in thermoplastic material excluding the motor Photo 1 POS 1 2 3 4 5 6 7 8 9 10 11 12 13 Part Descr Set Screws Front Casing O ring Casing Thrust Bush Shaft Ring Impeller Thrust Bearing Impeller Int...

Страница 20: ...3 3 If it s necessary to remove the external magnet Photo N 4 in blue from the motor shaft proceed unscrewing the grub screw with an Allen key and then use a puller to avoid damage to the motor shaft...

Страница 21: ...aft until it touches the shaft shoulder Then screw the grub screw to fix it Photo 7 Photo 8 Photo 9 The parts that can be periodically replaced are O ring part 3 in the section drawing Bearings part 9...

Страница 22: ...the fan at the back of the motor and rotate it by hand to check the free rotation of the unite In case of excessive friction or anomalous noises disassemble the group instructions paragraph 4 4 and fi...

Страница 23: ...lease contact GemmeCotti or our distributors To have the spare parts it s necessary to communicate the model of the pump the size the material the serial number the year of construction and the number...

Страница 24: ...for safety reasons the value of NPSH of the system NPSH available should be at least 1 m higher than the value of NPSH required written on the performance curves to prevent lack of lubrication or dry...

Страница 25: ......

Страница 26: ...social media social media social media social media social media social media social media social media social media social media social media social media social media Follow us on social media PROFE...

Страница 27: ...Turkish engineering technology products in 135 countries in the world today...

Страница 28: ...4 444 444EK N Is tma So utma San Tic Ltd ti Dudullu Organize Sanayi B lgesi Des Sanayi Sitesi 107 Sk B14 Blok No 2 mraniye stanbul Turkey Phone 90 216 232 24 12 Fax 90 216 660 13 08 info ekinendustriy...

Отзывы: