background image

- 7 - 

Installation 

 

 
 

3.3.

 

Electrical connection 

The inside unit has to be supplied with electricity; its voltage is 9 VAC. 

Please use the “9VAC – in” connecting clamps and 

only use the 

power supply provided with your TOCAnet product. 

 

Inside and outside units have to be connected to the RS-485 bus using 
a bell wire or Cat 5/6 cable 

(see the connection scheme below)

Minimum wire diameter required is 0.6 mm². For the power supply of 
the scanner unit, a wire diameter of 0,75mm² (gauge 21) is necessary. 

 
Each door opener has to be connected to a separate power supply! Do 

not use the ekey

® 

adapter for powering any other electronic devices! 

 
The connection wire between outside and inside units is to be run 

separately from electronic house installations, as they send out signals 
in the lower voltage area, which can be irritated by other neighbouring 

live power cables.  
 

The cables are not protected against reversed polarity. 
 

 

 

 

Note: 

It is strongly recommended to have the electrical connection done only 

by qualified personnel! 

Содержание TOCAnet

Страница 1: ...INSTALLATION MANUAL ekey TOCAnet Networked access system with fingerscan...

Страница 2: ...2 Index of contents INDEX OF CONTENTS 2 SCOPE OF SUPPLY 3 DEVICE OVERVIEW 5 INSTALLATION 6 OPERATION 8 POSSIBLE PROBLEM AREAS AND SOLUTIONS 9 TECHNICAL DATA 10 FURTHER INFORMATION 10 NOTES 11...

Страница 3: ...de unit Inside unit IU 4 screws and pins for outside unit External power supply User list Warranty card Installation and operating manual Quick user guide Power supply Inside unit Manual Warranty card...

Страница 4: ...n ekey TOCAnet installation In order to set up a fully functioning ekey TOCAnet installation the following hardware and software components are necessary CD ROM with ekey TOCAnet Software LAN RS 485 c...

Страница 5: ...elays are equipped with a change over contact which is freely usable the maximum switching power is 250V 5A Programming Programming and configuration of ekey TOCAnet is done by using the software ekey...

Страница 6: ...similar screws directly on the wall The outside unit splash water resistant has to be installed in a place where it is safe from the impact of heavy rain or snowfall as well as from too strong an inc...

Страница 7: ...he power supply of the scanner unit a wire diameter of 0 75mm gauge 21 is necessary Each door opener has to be connected to a separate power supply Do not use the ekey adapter for powering any other e...

Страница 8: ...er sensor between the 2 green illuminated arrows b Starting from the finger joint place the finger flat over the sensor It is very important that the whole finger is placed flat over the sensor and no...

Страница 9: ...Open the described ports in the firewall for UDP communication LED of external unit is blinking green Fingerprint sensor can not be activated Maybe the sensor is defect Contact an authorized ekey TOCA...

Страница 10: ...o outside unit 60x95x55 mm o inside unit 140x128x48 mm Installation height of outside unit o approx 135 cm upper edge Operating voltage of internal unit o 9 VAC or 12 VDC with controlled external adap...

Страница 11: ...11 Notes 7 Notes...

Страница 12: ...ey biometric systems subject to changes errors and omissions excepted No responsibility is accepted for the correctness of the information given ekey biometric systems GmbH Co KG Lunzerstra e 64 A 403...

Отзывы: