background image

- 1 - 

1.

 

Product Summary

XC

8602ME-B 

outdoor  optical  receiver  is  a  new 

860M

Hz  optical  receiver. With  wide 

receiving  optical  power  range,  high  output  level,  low  power  consumption  and compact 
structure.  It  is  very  easy  to  install.  It  is  the  ideal  equipment  to  build  the high-
performance NGB network. 

2.

 

Performance Characteristics

High responsivity PIN photoelectric conversion tube.

860M

Hz bandwidth design.

Optimized circuit design, preceding stage adopts SMT process and post stage adopts

 

typical module amplifier circuit, make the photoelectronic signal transmission more

 

smooth.

Power doubler output, with high gain and low distortion.

Optical AGC control, when the input optical power range is 

7

~+

2dBm, the output

 

level, CTB and CSO basically unchanged.

Can be extended with remote network management, easy to access the network

 

management system.

The fiber port and network management port can be selected external (I type) or internal

 

(II type). 

3.

 

Technique Parameter

3.1 Link testing conditions 

The  technique  parameters  of  this  manual  according  to  the  measuring  method  of  GY/T 

194-2003  <Specifications  and  methods  of  measurement  on  optical  node  used  in  CATV

 

systems>, and tested in the following conditions.

Testing conditions:

Forward  path  optical  receiver  part:  with  10km  standard  optical  fiber,  passive  optical

 

attenuator and standard optical transmitter composed the testing link. Set 

59 PAL-D 

analog

 

TV channel signal at range of 

45/87MHz

550MHz

 under the specified link loss. Transmit

 

digital modulated signal at range of 

550MHz

862MHz

, the digital modulated signal

 

level 

(in 

8 MHz

 bandwidth) is 

10dB

 lower than analog signal carrier level. When the input

 

optical 

power of optical receiver is 

-1dBm

, the RF output level is 

108dBμV

, with 

8dB

 output

 

tilt, 

measure the 

C/CTB

C/CSO

 and 

C/N

.

Note

: When the rated output level is the system full configuration and the receiving optical

 

power is 

-1dBm

, equipment meets the maximum output level of link index. When the system

 

configuration  reduce  (that  is,  actual  transmission  channels  reduce),  the  output  level  of

 

equipment will be increased.

Friendly Notice

:  Suggest  you  setting  the  RF  signal  to 

6~9dB

  tilt  output  in  the  practical

 

engineering application to improve the nonlinear index (behind the node) of the cable system.

Содержание XC8602ME-B

Страница 1: ...XC8602ME B Optical Receiver Manual Optical Receiver Specification ...

Страница 2: ...al according to the measuring method of GY T 194 2003 Specifications and methods of measurement on optical node used in CATV systems and tested in the following conditions Testing conditions Forward path optical receiver part with 10km standard optical fiber passive optical attenuator and standard optical transmitter composed the testing link Set 59 PAL D analog TV channel signal at range of 45 87...

Страница 3: ... CTB dB 65 C CSO dB 60 RF Parameters Frequency Range MHz 45 862 Flatness in Band dB 0 75 Rated Output Level dBμV 108 Max Output Level dBμV 116 7 2dBm optical power received Output Return Loss dB 16 Output Impedance Ω 75 EQ Range dB 0 20 ATT Range dB 0 20 Generic Characteristic Power Voltage V A AC 150 265 V B AC 35 90 V Operating Temperature 40 60 Consumption VA 18 Dimension mm 220 L 205 W 65 H No...

Страница 4: ...g port or external optional 4 Working indicator 5 Optical power display tube 6 Power interface 7 Switching power supply 8 Power cord in 9 AC60V power pass inserter 10 Output 20dB test port 11 Output 1 12 FZ110 or FP204 13 AC60V feed 14 AC60V power pass inserter 15 Output 2 16 Network management interface 17 Fiber in 18 Network cable in ...

Страница 5: ...an be direct connected and change the computer IP to 192 168 1 XXX XXX is any number from 0 to 255 except 168 start upper computer network management software then search the device and log in 3 Right click device icon and choose modify the device IP 4 Enter new IP address gateway and subnet mask 5 Click modify then exit it is done There will show new IP address and gateway on operational logbook ...

Страница 6: ... signal is too low 1 Check the received optical power of the optical contact point and make appropriate adjustments to make it in the specified range 2 Improve the optical received power of the optical contact point by cleaning the optical fiber connector or adapter etc methods Specific operation methods see Clean and maintenance method of the optical fiber connector 3 Check the RF input signal le...

Страница 7: ...nnector component or bulkhead with a fiberscope If the connector is dirty clean it with a cleaning technique following these steps 1 Carefully pull off the optical fiber active connector from the adapter The optical fiber active connector should not aim at the human body or the naked eyes to avoid accidental injury 2 Wash carefully with good quality lens wiping paper or medical degrease alcohol co...

Отзывы: