2. General
notes
Use of these fresh air hose devices 6500/6501 presupposes full knowledge of and adherence to this information brochure.
The devices described here are designed exclusively for the use named in the information brochure.
Repairs and the replacement of spare parts may only be carried out by trained specialists, using only original spare parts.
EKASTU Safety GmbH assumes liability within the framework of the General Terms and Conditions.
Any liability is ruled out if:
•
The device has undergone technical modifications
•
The inspections and/or repairs have not been carried out or not carried out correctly,
•
The device was not used in the intended fashion,
•
The seals have been removed or are damaged.
Otherwise the manufacturer is not liable for damage caused as a result of non-adherence to this information brochure.
Otherwise the General Terms and Conditions of EKASTU Safety GmbH apply. Insofar as these are not available they will
be sent to you on request.
3. Device
versions
The complete fresh air hose device 6500 in accordance with DIN EN 138 comprises the basic unit 6500 in connection with
an air feed hose and a full face mask.
The complete fresh air hose device 6501 in accordance with DIN EN 138 comprises the basic unit 6501 in connection with
an air feed hose, a full face mask and a blower.
4. Conditions for use
4.1. Approvals
The EC type examinations for the fresh air hose devices in the series 6500/6501 were carried out based on the norm
DIN EN 138 and granted the
-mark by the technical committee for ‘Personal Protective Equipment’ of the federation of
statutory accident insurance institutions (Hauptverband der gewerblichen Berufsgenossenschaften), accreditation no. 299.
4.2.
Areas of use
The fresh air hose devices in the series 6500/6501 comprising the basic unit 6500/6501, a full-face mask, an air feed hose
and for the series 6501, also a blower. The breathing apparatus is only functional and ready for use once the connections
between these components have been tightly sealed.
The device can be used in accordance with the valid conditions in the commercial professional associations in
atmospheres where the air pollutants display concentrations of up to 1,000 times the limit value*. Please ensure that the
suction strainer/blower is mounted and securely fixed in a position where there is unpolluted air. Particular care must be
taken in the case of harmful gas that is heavier than air and therefore concentrated close to the floor. In this case we
recommend mounting the suction end of the hose at a height of at least 1.5 m.
*: Limit values in the sense of this information are the highest permitted concentrations (without breathing protection) of
harmful gases and/or particles in the surrounding atmosphere (MAK / TRK - values).
Fresh air hose devices are isolated units that are the safest type of breathing apparatus. Their use becomes necessary if
one of the following conditions is fulfilled:
- if the oxygen content of the surrounding atmosphere is below 17 % by volume,
- if the type or concentration of the pollutants is unknown,
- If the type, combination or concentration of pollutants rules out the use of filter devices,
- if the conditions of use are not exactly known,
- if the opportunity of a rapid withdrawal from the hazardous area is not given,
- if the intake of even the smallest quantities of the pollutant causes damage to health,
- if the composition of the surrounding atmosphere can deteriorate (e.g. in restricted spaces such as ditches, containers,
ducts etc.).