Residual risks
-
Keep away from the appliance unskilled personel.
-
The appliance contains electrical parts and must never be washed with a jet of water or steam.
-
To avoid wrong installation, the right gas connection is showed on a label that identifies the correct
gas type to use.
-
The appliance is electrically connected: before attempting any cleaning operation, cut power to the
appliance.
-
The removable parts of the cooking top, after the cleaning operation, must be placed correctly in
their housing in order to avoid anomalous and dangerous functioning of the burners.
4. Gas connection
Connect the appliance to a gas cylinder or mains gas pipe according to the prescriptions of
standards (as per current national installation norms and subsequent amendments). To connect gas,
use an approved rigid metal pipe in copper or stainless-steel (the current national installation norms
and subsequent amendments). The appliance is equipped with threaded GJ
½
” pipes for gas inflow.
Check if the appliance is designed to operate on the same type of gas as supplied and if pressure is set
for that type of gas. Otherwise, carry out the operations indicated in paragraph “ADAPTING TO
DIFFERENT TYPES OF GAS”.
IMPORTANT
-
Make sure that supply pressure matches the values indicated in the table “Burner
and nozzle characteristics” (tab.1).
If supply pressures do not match the values in the table, eliminate the cause of this, or inform the
gas company and do not use the appliance. Connection with rigid or flexible metal pipes must not
cause stresses to the appliance pipe (“train”).
5. Electric connection
Before performing the electric connection
, make sure that:
-
the relief valve and the system can stand the appliance load (see data on the rating plate);
-
THE SUPPLY SYSTEM IS EQUIPPED WITH AN APPROPRIATE GROUND CONNECTION IN
ACCORDANCE WITH THE REGULATIONS IN FORCE;
-
the omnipolar system used for the connection can be easily reached with the appliance installed.
In the grid-connected mode, between the appliance and the grid an omnipolar switch must be
inserted, having a 3 mm minimum opening between contacts, suitable to the load used and in
accordance with the regulations in force.
The yellow/green earth cable must not be interrupted by
the switch.
The appliance must be connected to an equipotential system whose efficiency must first be checked
according to current legal regulations. When the appliance is operating, the supplied voltage must not
deviate from the nominal voltage value of ±10%.
If the power cable needs replacing, it must be secured through the cable gripper and must have the
following characteristics:
-
type (HAR) H07RN-F with three conductors
-
minimum diameter: 0.75 mm
2
.