background image

 WARNING

If the unit begins to emit smoke, smells like something is burning, or makes strange noises, 

disconnect all power connections immediately and contact your EIZO representative for advice.

Attempting to use a malfunctioning unit may result in fire, electric shock, or equipment damage.

Do not disassemble or modify the unit.

Opening the cabinet or modifying the unit may result in fire, electric shock, or burn.

Refer all servicing to qualified service personnel.

Do not attempt to service this product yourself as opening or removing covers may result in fire, electric 
shock, or equipment damage.

Keep small objects or liquids away from the unit.

Small objects accidentally falling through the ventilation slots into the cabinet or spillage 

into the cabinet may result in fire, electric shock, or equipment damage. If an object or 
liquid falls/spills into the cabinet, unplug the unit immediately. Have the unit checked by 
a qualified service engineer before using it again.

Place the unit at a sturdy and stable place.

A unit placed on an inadequate surface may fall and result in injury or equipment damage. If the unit falls, 

disconnect the power immediately and ask your local EIZO representative for advice. Do not continue using 

a damaged unit. Using a damaged unit may result in fire or electric shock.

Use the unit in an appropriate location.

Otherwise, fire, electric shock, or equipment damage may result.

 • Do not place outdoors.

 • Do not place in any form of transportation (ships, aircraft, trains, automobiles, etc.).

 • Do not place in dusty or humid environments.

 • Do not place in locations where water may be splashed on the screen (bathrooms, kitchens, 

etc.)

 • Do not place in locations where steam comes in direct contact with the screen.

 •

Do not place near heat generating devices or humidifiers.

 • Do not place in locations where the product is subject to direct sunlight.

 •

Do not place in environments with inflammable gas.

 •

Do not place in environments with corrosive gases (such as sulfur dioxide, hydrogen sulfide, 

nitrogen dioxide, chlorine, ammonia, and ozone)

 • Do not place in environments with dust, components that accelerate corrosion in the 

atmosphere (such as sodium chloride and sulfur), conductive metals, and so on

To avoid danger of suffocation, keep the plastic packing bags away from babies and children.
Use the enclosed power cord and connect to the standard power outlet in your country.

Be sure to use within the rated voltage of the power cord. Otherwise, fire or electric shock may result.
Power supply: 100-240Vac 50/60Hz

To disconnect the power cord, grasp the plug firmly and pull.

Tugging on the cord may damage and result in fire or electric shock.

The equipment must be connected to a grounded main outlet.

Failure to do so may result in fire or electric shock.

Use the correct voltage.

 •

The unit is designed for use with a specific voltage only. Connection to another voltage than specified in this 

“Instructions for Use” may cause fire, electric shock, or equipment damage.

 

Power supply: 100-240Vac 50/60Hz

 •

Do not overload your power circuit, as this may result in fire or electric shock.

4

PRECAUTIONS

Содержание RadiForce RX370

Страница 1: ...yourself with safe and effective usage Please retain this manual for future reference For monitor adjustment and settings refer to the Installation Manual For the latest product information including...

Страница 2: ...ted specifically for use in the region to which it was originally shipped If operated outside this region the product may not perform as stated in the specifications No part of this manual may be repr...

Страница 3: ...tes Main Power Switch Press to turn the monitor s main power off Main Power Switch Press to turn the monitor s main power on Power button Press to turn the monitor s power on or off Alternating curren...

Страница 4: ...ny form of transportation ships aircraft trains automobiles etc Do not place in dusty or humid environments Do not place in locations where water may be splashed on the screen bathrooms kitchens etc D...

Страница 5: ...he unit securely Otherwise the unit may become detached resulting in injury and or equipment damage Before installation make sure that desks walls or any other installation surface has adequate mechan...

Страница 6: ...slots prevents proper airflow and may result in fire electric shock or equipment damage Do not touch the plug with wet hands Doing so may result in electrical shock Use an easily accessible power out...

Страница 7: ...e monitor be turned off periodically The backlight of the LCD panel has a fixed lifetime Depending on the usage pattern such as usage for long continuous periods the lifespan of the backlight may run...

Страница 8: ...accuracy of the Integrated Front Sensor at a level equivalent to that of the external sensor Attention The display status of the monitor may change unexpectedly due to an operating error or unexpected...

Страница 9: ...ctions 14 Chapter 2 Installation Connection 15 2 1 Before Installing the Product 15 Installation Requirements 15 2 2 Connecting Cables 16 2 3 Turning On the Power 19 2 4 Charging quickly with USB Type...

Страница 10: ...a pixel level and displays them respectively in optimal gradations Simple wiring In addition to a DisplayPort input terminal an output terminal is also provided From the output terminal a signal can...

Страница 11: ...ng RadiCS LE that is attached to the monitor you can manage history related to the monitor and the SelfCalibration target and execution schedule The RadiCS monitor quality control software enables you...

Страница 12: ...ng mode Backlight Saver A feature that temporarily increases brightness to improve the visibility of diagnostic images Instant Backlight Booster Note The RadiCS RadiCS LE software allows you to displa...

Страница 13: ...on that assigns any CAL Switch mode to a part of the screen and displays an image Point and Focus Displaying or hiding the PinP sub window Hide and Seek Switching PCs used to operate USB devices Switc...

Страница 14: ...nitor so as not to drop it Do not hold the sensor section on the front side of the monitor 6 Stand Adjusts the height and angle tilt and swivel of the monitor 7 USB Type C connector quick charge only...

Страница 15: ...ace this product on a lacquer coated desk the color may adhere to the bottom of the stand due to the composition of the rubber Check the desk surface before use Installation Requirements When installi...

Страница 16: ...ighten the fasteners to secure the connector Signal cable DD200DL optional Signal cable PP300 or Attention The monitor has two types of DisplayPort connectors input and output When connecting the moni...

Страница 17: ...When using a daisy chain connection connect the cable to the input connector To set up a daisy chain connection you need to select Signal Format DisplayPort 1 on the Administrator Settings menu and s...

Страница 18: ...vice USB connected peripheral device to the monitor USB cable UU300 Attention When connecting the monitor to a PC on which RadiCS RadiCS LE has been installed connect the cable to Remove the cap befor...

Страница 19: ...age 21 for additional advice Attention For the maximum power saving it is recommended that the Power button be turned off When not using the monitor you can turn off the main power supply or disconnec...

Страница 20: ...right edges of the monitor with both hands and adjust the screen height tilt and swivel the screen to the optimum position for performing tasks Attention After the adjustment is finished make sure tha...

Страница 21: ...version For details refer to the Installation Manual on the CD ROM 2 The message below appears This message appears when the signal is not input correctly even though the monitor is functioning proper...

Страница 22: ...z 127 kHz Vertical scan frequency 2 29 0 Hz 61 5 Hz 720 400 69 Hz 71 Hz Frame Synchronization mode 29 5 Hz 30 5 Hz 59 0 Hz 61 0 Hz Dot clock DisplayPort DVI 25 MHz 215 MHz 25 MHz 165 MHz 165 MHz 215 M...

Страница 23: ...Input Detection off no external load is connected 5 When the USB upstream port is not connected DP Power Save On Signal Format DisplayPort 1 Version 1 1 no external load is connected 4 2 Compatible Re...

Страница 24: ...e graphics board refer to our web site www eizoglobal com Calibration Kit RadiCS UX2 Ver 5 0 8 or later RadiCS Version Up Kit Ver 5 0 8 or later Network QC Management Software RadiNET Pro Ver 5 0 8 or...

Страница 25: ...could influence limit or result in malfunction of the monitor Install the equipment in a controlled environment where such effects are avoided Classification of Equipment Type of protection against e...

Страница 26: ...uipment If adjacent or stacked use is necessary the equipment or system should be observed to verify normal operation in the configuration in which it will be used When using a portable RF communicati...

Страница 27: ...discharge ESD IEC EN61000 4 2 8 kV contact discharge 15 kV air discharge 8 kV contact discharge 15 kV air discharge Floors should be wood concrete or ceramic tile If floors are covered with synthetic...

Страница 28: ...a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Note 1 UT is the a c mains voltage prior to ap...

Страница 29: ...um separation distance m IEC EN60601 test level V m Compliance level V m 385 380 390 TETRA 400 Pulse modulation b 18 Hz 1 8 0 3 27 27 450 430 470 GMRS 460 FRS 460 FM 5 kHz deviation 1 kHz sine 2 0 3 2...

Страница 30: ...d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not list...

Страница 31: ...ollowing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which t...

Страница 32: ...Corporation All rights reserved 1st Edition February 19th 2021 Printed in Japan 00N0N214A1 IFU RX370 6 www eizoglobal com Carl Benz Stra e 3 76761 R lzheim Germany 8 5B 153 Shimokashiwano Hakusan Ishi...

Отзывы: