E
9
2
IMAGING ADJUSTMENT
- Screen menu -
All of the icons shown in the ScreenManager 'Screen' menu are described
below.
•
Allow the monitor to stabilize for at least 30 minutes before making
image adjustments.
Brightness, Contrast, Size, Position
These functions are used to adjust the brightness, contrast, size and position
of the screen. For more information about how to adjust each of them,
please refer to the 'Quick Setup Guide', page 8.
Geometry, Tilt, Bright Uniformity
Image distortion, tilting and/or the imbalance of brightness over the entire
screen may be caused by the Earth's magnetic field. Use the 'Screen' menu’s
geometry (Side-Pincushion, Side-Pin Balance,
Trapezoi-
dal, Parallelogram) adjustment function to correct any geometric distor-
tion.
The tilt adjustment function adjusts both the image tilting and the bright
uniformity (the balance of brightness over the entire screen). For informa-
tion about how to adjust them, please refer to the
Trouble-
shooting on page 33.
Image distortion, tilting and/or the imbalance of brightness may also be
caused by any device that generates a magnetic field. If the above
adjustments are not effective, try the following approaches.
• Check to see if there are any nearby interfering electronic devices such
as another monitor, an electric motor, or a speaker (other than an
optional EIZO i·Sound speaker unit). If so, move the device or move
the monitor.
• It is sometimes possible to correct distortion, tilting or the imbalance of
brightness by reorienting the monitor.
2 IMAGING ADJUSTMENT
Содержание FlexScan T57S
Страница 1: ...English...
Страница 39: ......
Страница 44: ...128 APPENDIX Dimensions Abmessungen Dimensions mm...