PRECAUTIONS

 CAUTION

Use an easily accessible power outlet.

This will ensure that you can disconnect the power quickly in case of a problem.

Periodically clean the area around the plug.

Dust, water, or oil on the plug may result in fire.

Unplug the unit before cleaning it.

Cleaning the unit while it is plugged into a power outlet may result in electric shock.

If you plan to leave the unit unused for an extended period, disconnect the 
power cord from the wall socket after turning off the power switch for the 
safety and the power conservation.

Notice for this monitor

In order to suppress the luminosity change by long-term use and to maintain the stable luminosity, use of a 
monitor in lower brightness is recommended.

The LCD panel is manufactured using high-precision technology. However, note that the appearance of any 
missing pixels or lit pixels does not indicate damage to the LCD monitor.
Percentage of effective pixels : 99.9994% or higher.

The backlight of the LCD panel has a fixed life span. When the screen becomes dark or begins to flicker, 
please contact your dealer.

Do not press on the panel or edge of the frame strongly, as this may result in damage to the screen. There 
will be prints left on the screen if the pressed image is dark or black. If pressure is repeatedly applied to the 
screen, it may deteriorate or damage your LCD panel. Leave the screen white or black to decrease the prints.

When  the  screen  image  is  changed  after  displaying  the  same  image  for  extended  periods  of  time,  an 
afterimage may appear. Use the screen saver or timer to avoid displaying the same image for extended 
periods of time.

When  the  monitor  is  cold  and  brought  into  a  room  or  the  room  temperature  goes  up  quickly,  dew 
condensation may occur inside and outside the monitor. In that case, do not turn the monitor on and wait until 
dew condensation disappears, otherwise it may cause some damages to it.

Do not scratch or press on the panel with any sharp objects, such as a pencil or pen as this may result in 
damage to the panel. Do not attempt to brush with tissues as this may scratch the LCD panel.

To use the monitor comfortably

An excessively dark or bright screen may affect your eyes. Adjust the brightness of the monitor according to 
the environmental conditions.

Staring at the monitor for a long time tires your eyes. Take a 10-minute rest every hour.

Содержание FlexScan MX300W

Страница 1: ...lation 10 2 1 Environmental Settings 10 2 2 Making Use of USB Universal Serial Bus 12 3 Screen Adjustment and Settings 13 3 1 Basic Operation and Functions 13 3 2 Color Adjustment 15 3 3 Power save Se...

Страница 2: ...though every effort has been made to ensure that this manual provides up to date information please note that EIZO monitor specifications are subject to change without notice Macintosh is registered t...

Страница 3: ...low Location of the Caution Statements Symbol on the Unit Symbol Location This symbol indicates Front Power switch Touch to turn the monitor s power on or off Rear Name Plate Alternating current Rear...

Страница 4: ...lace outdoors Do not place in the transportation system ship aircraft trains automobiles etc Do not place in a dusty or humid environment Do not place in a location where the steam comes directly on t...

Страница 5: ...us if it enters the eyes or mouth If any part of the skin or body comes in direct contact with the panel please wash thoroughly If some physical symptoms result please consult your doctor Lamps contai...

Страница 6: ...r Do not press on the panel or edge of the frame strongly as this may result in damage to the screen There will be prints left on the screen if the pressed image is dark or black If pressure is repeat...

Страница 7: ...The quality control software RadiCS LE for Windows used to calibrate the monitor is included refer to the EIZO LCD Utility Disk The utility software ScreenManager Pro for Medical for Windows to contr...

Страница 8: ...tton 3 Enter button 4 Control buttons Left Down Up Right 5 Power button 6 Power indicator Indicator status Operation status Blue The screen is displayed Orange Power saving Off Power off ScreenManager...

Страница 9: ...E is quality control software used to calibrate the monitor and manage the calibration history A PC must be connected to the monitor with the supplied USB cable Refer to the description later ScreenMa...

Страница 10: ...less of whether or not the computer is running Displaying Two Screens Simultaneously It is possible to display two screens on a single monitor at the same time by using one graphics board with DVI D2...

Страница 11: ...connector and the computer using the DD200DL BK signal cable After connecting the cable connectors tighten the screws of the connectors to secure the coupling Connectors on the PC Signal cable Connect...

Страница 12: ...peripherals is recommended If the monitor is in the power saving mode or if the monitor is connected to the power outlet with the monitor turned off all the devices connected to the USB ports upstream...

Страница 13: ...tments and Settings 1 Select the desired sub menu icon using and press The sub menu appears 2 Use to select the desired setting icon and press The setting menu appears 3 Use to make all required adjus...

Страница 14: ...djust the menu position Menu Off Timer Set the menu displaying time Translucent Set the transparency of the background Orientation Set the orientation of the Adjustment menu Power Indicator Make non l...

Страница 15: ...pose DICOM Select this option to display images in the DICOM mode Custom Available for making desired setting CAL Used for monitor calibration Text Suitable for displaying texts for word processing or...

Страница 16: ...ode DICOM Custom CAL Text Brightness Temperature Gamma Saturation Hue Gain 6 colors Reset These settings can be also adjusted on the CAL Switch menu See CAL Switch NOTE Allow the LCD monitor to stabil...

Страница 17: ...set the gamma value 1 8 2 6 Saturation To change the saturation 100 100 Setting the minimum level 100 turns the image to the monochrome NOTE The Saturation adjustment may cause undisplayable color to...

Страница 18: ...to the monitor s USB both the upstream and the downstream ports Therefore power consumption of the monitor will change according to the connected devices even if the monitor is in a power saving mode...

Страница 19: ...te for additional 90 minutes Extension of operation time can be set without limitation Power Resumption Procedure Press to return a normal screen NOTE The off timer function works while the PowerManag...

Страница 20: ...n Since the verticalresolution and the horizontal resolution are enlarged at different rates some images may appeardistorted Enlarged Displays the picture on the screen in full irrespective of the pic...

Страница 21: ...the monitor screen 90 in clockwise direction NOTE Be sure to turn the monitor screen after pulling up the screen to the uppermost position of the stand and setting the screen tilted upward Tips If yo...

Страница 22: ...hen the monitor functions properly This message appears when no signal is input This is displayed for about 40 seconds The message shown left may appear because some PCs do not output the signal soon...

Страница 23: ...ed Smoothing setting may not be required depending on the display resolution You cannot choose the smoothing icon 11 The Main menu of Adjustment menu does not start Check for Adjustment Lock function...

Страница 24: ...0 mm 100 mm Thickness of plate 2 6 mm Strong enough to support weight of the monitor unit except the stand and attachments such as cables Attach an arm or stand to meet the following tilt angles of th...

Страница 25: ...ly moistened cloth using a mild detergent Do not spray wax or cleaner directly into the cabinet For details refer to the manual of the PC LCD Panel Panel Protector The LCD surface can be cleaned with...

Страница 26: ...Power switch Off 170 W with USB Less than 2 W for single signal input without USB 1W or less Input Signal Connector SIGNAL 1 DVI D Dual Link SIGNAL 2 DVI D Single Link HDCP compliant Input Signal Dig...

Страница 27: ...3 9 175 6 9 3 9 2 42 0 67 0 06 0 06 0 06 0 06 0 93 0 93 2 01 3 54 2 24 SWIVEL Default settings Smoothing 3 CAL Switch Mode DICOM PowerManager DVI DMPM Screen Size Full Off Timer Disable Menu Settings...

Страница 28: ...return for 5V Hsync and Vsync 23 T M D S Clock 8 NC 16 Hot Plug Detect 24 T M D S Clock NC No Connection SIGNAL2 Applicable to SingleLink only Pin No Signal Pin No Signal Pin No Signal 1 T M D S Data...

Страница 29: ...Gamma Generally the relationship that the light intensity values of a monitor change nonlinearly to the input signal level is called Gamma Characteristic On the monitor low gamma values display the wh...

Страница 30: ...SA DPMS Video Electronics Standards Association Display Power Management Signaling The acronym VESA stands for Video Electronics Standards Association and DPMS stands for Display Power Management Sign...

Страница 31: ...ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rec...

Страница 32: ...1st Edition November 2007 03V22241A1 U M MX300W...