background image

SAFETY SYMBOLS

SAFETY SYMBOLS

This manual uses the safety symbols below. They denote critical information. Please read them carefully.

WARNING

Failure to abide by the information in a WARNING may result in serious injury and can 
be life threatening.

CAUTION

Failure to abide by the information in a CAUTION may result in moderate injury and/or 
propertyor product damage.

Indicates a prohibited action.

Indicates to ground for safety.

Copyright© 2007 EIZO NANAO CORPORATION All rights reserved. No part of this manual may be 
reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, 
mechanical, or otherwise, without the prior written permission of EIZO NANAO CORPORATION.
EIZO NANAO CORPORATION is under no obligation to hold any submitted material or information 
confidential unless prior arrangements are made pursuant to EIZO NANAO CORPORATION's receipt 
of said information. Although every effort has been made to ensure that this manual provides up-to-date 
information, please note that EIZO monitor specifications are subject to change without notice.

Macintosh is registered trademarks of Apple Inc.
VGA is a registered trademark of International Business Machines Corporation.
DPMS is a trademark and VESA is a registered trademark of Video Electronics Standards Association.
Windows is a registered trademark of Microsoft Corporation.
PowerManager and RadiCS are trademarks of EIZO NANAO CORPORATION.
ScreenManager, FlexScan and EIZO are registered trademarks of EIZO NANAO CORPORATION

Product specifications may vary depending on the region.  
Confirm the specifications in the manual written in the language of the region of purchase.

•  It shall be assured that the final system is in compliance to IEC60601-1-1 requirement.
•   Power  supplied  equipment  can  emit  electromagnetic  waves,  that  could  influence,  limit  or  result  in 

malfunction of the monitor. 

  Install the equipment in a controlled environment, where such effects are avoided.
•  This is a monitor intended for use in a medical image system.

Содержание FlexScan MX300W

Страница 1: ...lation 10 2 1 Environmental Settings 10 2 2 Making Use of USB Universal Serial Bus 12 3 Screen Adjustment and Settings 13 3 1 Basic Operation and Functions 13 3 2 Color Adjustment 15 3 3 Power save Se...

Страница 2: ...though every effort has been made to ensure that this manual provides up to date information please note that EIZO monitor specifications are subject to change without notice Macintosh is registered t...

Страница 3: ...low Location of the Caution Statements Symbol on the Unit Symbol Location This symbol indicates Front Power switch Touch to turn the monitor s power on or off Rear Name Plate Alternating current Rear...

Страница 4: ...lace outdoors Do not place in the transportation system ship aircraft trains automobiles etc Do not place in a dusty or humid environment Do not place in a location where the steam comes directly on t...

Страница 5: ...us if it enters the eyes or mouth If any part of the skin or body comes in direct contact with the panel please wash thoroughly If some physical symptoms result please consult your doctor Lamps contai...

Страница 6: ...r Do not press on the panel or edge of the frame strongly as this may result in damage to the screen There will be prints left on the screen if the pressed image is dark or black If pressure is repeat...

Страница 7: ...The quality control software RadiCS LE for Windows used to calibrate the monitor is included refer to the EIZO LCD Utility Disk The utility software ScreenManager Pro for Medical for Windows to contr...

Страница 8: ...tton 3 Enter button 4 Control buttons Left Down Up Right 5 Power button 6 Power indicator Indicator status Operation status Blue The screen is displayed Orange Power saving Off Power off ScreenManager...

Страница 9: ...E is quality control software used to calibrate the monitor and manage the calibration history A PC must be connected to the monitor with the supplied USB cable Refer to the description later ScreenMa...

Страница 10: ...less of whether or not the computer is running Displaying Two Screens Simultaneously It is possible to display two screens on a single monitor at the same time by using one graphics board with DVI D2...

Страница 11: ...connector and the computer using the DD200DL BK signal cable After connecting the cable connectors tighten the screws of the connectors to secure the coupling Connectors on the PC Signal cable Connect...

Страница 12: ...peripherals is recommended If the monitor is in the power saving mode or if the monitor is connected to the power outlet with the monitor turned off all the devices connected to the USB ports upstream...

Страница 13: ...tments and Settings 1 Select the desired sub menu icon using and press The sub menu appears 2 Use to select the desired setting icon and press The setting menu appears 3 Use to make all required adjus...

Страница 14: ...djust the menu position Menu Off Timer Set the menu displaying time Translucent Set the transparency of the background Orientation Set the orientation of the Adjustment menu Power Indicator Make non l...

Страница 15: ...pose DICOM Select this option to display images in the DICOM mode Custom Available for making desired setting CAL Used for monitor calibration Text Suitable for displaying texts for word processing or...

Страница 16: ...ode DICOM Custom CAL Text Brightness Temperature Gamma Saturation Hue Gain 6 colors Reset These settings can be also adjusted on the CAL Switch menu See CAL Switch NOTE Allow the LCD monitor to stabil...

Страница 17: ...set the gamma value 1 8 2 6 Saturation To change the saturation 100 100 Setting the minimum level 100 turns the image to the monochrome NOTE The Saturation adjustment may cause undisplayable color to...

Страница 18: ...to the monitor s USB both the upstream and the downstream ports Therefore power consumption of the monitor will change according to the connected devices even if the monitor is in a power saving mode...

Страница 19: ...te for additional 90 minutes Extension of operation time can be set without limitation Power Resumption Procedure Press to return a normal screen NOTE The off timer function works while the PowerManag...

Страница 20: ...n Since the verticalresolution and the horizontal resolution are enlarged at different rates some images may appeardistorted Enlarged Displays the picture on the screen in full irrespective of the pic...

Страница 21: ...the monitor screen 90 in clockwise direction NOTE Be sure to turn the monitor screen after pulling up the screen to the uppermost position of the stand and setting the screen tilted upward Tips If yo...

Страница 22: ...hen the monitor functions properly This message appears when no signal is input This is displayed for about 40 seconds The message shown left may appear because some PCs do not output the signal soon...

Страница 23: ...ed Smoothing setting may not be required depending on the display resolution You cannot choose the smoothing icon 11 The Main menu of Adjustment menu does not start Check for Adjustment Lock function...

Страница 24: ...0 mm 100 mm Thickness of plate 2 6 mm Strong enough to support weight of the monitor unit except the stand and attachments such as cables Attach an arm or stand to meet the following tilt angles of th...

Страница 25: ...ly moistened cloth using a mild detergent Do not spray wax or cleaner directly into the cabinet For details refer to the manual of the PC LCD Panel Panel Protector The LCD surface can be cleaned with...

Страница 26: ...Power switch Off 170 W with USB Less than 2 W for single signal input without USB 1W or less Input Signal Connector SIGNAL 1 DVI D Dual Link SIGNAL 2 DVI D Single Link HDCP compliant Input Signal Dig...

Страница 27: ...3 9 175 6 9 3 9 2 42 0 67 0 06 0 06 0 06 0 06 0 93 0 93 2 01 3 54 2 24 SWIVEL Default settings Smoothing 3 CAL Switch Mode DICOM PowerManager DVI DMPM Screen Size Full Off Timer Disable Menu Settings...

Страница 28: ...return for 5V Hsync and Vsync 23 T M D S Clock 8 NC 16 Hot Plug Detect 24 T M D S Clock NC No Connection SIGNAL2 Applicable to SingleLink only Pin No Signal Pin No Signal Pin No Signal 1 T M D S Data...

Страница 29: ...Gamma Generally the relationship that the light intensity values of a monitor change nonlinearly to the input signal level is called Gamma Characteristic On the monitor low gamma values display the wh...

Страница 30: ...SA DPMS Video Electronics Standards Association Display Power Management Signaling The acronym VESA stands for Video Electronics Standards Association and DPMS stands for Display Power Management Sign...

Страница 31: ...ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rec...

Страница 32: ...1st Edition November 2007 03V22241A1 U M MX300W...

Отзывы: