Gamma
*
-
*
-
-
Saturation
*
-
*
*
*
Hue
*
-
*
*
*
Gain
*
-
-
-
-
C-Booster
*
-
-
*
*
Reset
*
-
*
*
*
●
Allow the LCD monitor to stabilize for at least 20 minutes before making image adjustments. (Allow
the monitor to warm up for at least 20 minutes before making adjustments.)
●
Performing the <Reset> of the <Color> menu returns the color settings of the selected mode to the
default settings.
●
The values shown in percentages represent the current level within the specific adjustment. They are
available only as a reference tool. (To create a uniform white or black screen, the percentages for each
will probably not be the same.)
Adjustment Contents
Menu
Function Descriptions
Adjustable range
Brightness
To set the brightness of the screen
0 ~ 100 %
●
When <BrightRegulator> is set "Enable", brightness of the screen automatically adjusted
depending on the surrounding brightness based on the manual brightness adjustment.
●
Directly pressing the up and down control buttons also can adjust the brightness.
To set the color temperature
4,000 ~ 10,000 K
in 500 K increments (including 9,300 K) Default
setting is off (normal white)
●
The values shown in the Kelvin are available only as a reference tool.
●
Setting the temperature under 4,000 K or over 10,000 K invalidates the color temperature
setting. (The color temperature's setting turns "OFF".)
To set the gamma value
1.8/2.0/2.2
●
If setting the gamma value, the using the monitor in the digital signal input is recommended.
Saturation
To change the saturation
-128 ~ 124
Setting the minimum level (-128) turns the image
to the monochrome.