Chapter 3. Field Installation
3.1. Introduction
The information in this chapter is intended for qualified installers only.
Warning
All antennas and equipment must be installed by a knowledgeable and professional in-
staller. NOTE: EION RECOMMENDS THE USE OF LIGHTNING SUPRESSORS IN
ALL INSTALLATION.
The information in this chapter is intended for qualified installers only. Before you begin to install
equipment in the field, you should develop a network plan, prepare the customer site, and configure
the equipment. The network plan describes the proposed system, including a link budget, detailed list
of all required hardware, LibraPlus units (RD and ER for P-P links; LCPE, CPE and Access Point for
P-MP), antenna locations, cable routing, equipment configuration settings, and other network require-
ments. (EION, Inc. offers Network Planning and Site Preparation support. For more information on
services and fees contact your Sales Representative or visit
http://www.eionwireless.com/
). Network
planning should include visits to proposed sites to verify the feasibility of the network plan and work
out the details. Installers will use the network plan document to guide them through final site preparation,
installation, configuration and field testing of each unit. You can see that a large amount of planning
and preparation work is required before equipment is ready to install. The better the preparation work,
the more problem-free the field installation will be.
Fig. 3.1. Installation Process
3.2. LibraPlus Point-to-Point Quick Setup
This section explains how to configure a pair of LibraPlus radios for simple point to point communic-
ation. Using this example will configure a link without any additional features such as security, routing,
filtering, or VLAN
Note that the distance in this example is set to 300 for bench testing. When the units are deployed in
the field, this value should be changed to the appropriate link distance.
• Default LibraPlus IP address 192.168.0.5
• Login to the unit using a SSH enabled utility such as Putty
• Default username: admin
• Default password: 123
Note
For quick configuration, copy and paste the commands listed below directly into the SSH or
serial interface of the radio.
23
Содержание LibraPlus 5845
Страница 1: ...www eionwireless com LibraPlus 5845 PN 5724 0003 Document version 1 74 Released on February 16 2010...
Страница 2: ...This page is intentionally left blank...
Страница 10: ...6 5 Show CPU load 109 6 6 Show uptime 109 6 7 Show interfaces 110 x LibraPlus User Manual...
Страница 24: ...Fig 2 10 Mounting Fig 2 11 Large Pipe Diameter Mounting Configuration 14 Description...
Страница 25: ...Fig 2 12 Small Pipe Diameter Mounting Configuration Fig 2 13 Wall Mounting Configuration 15 Description...
Страница 26: ...2 1 7 Specifications 16 Description...
Страница 32: ...Fig 2 15 Point to Multipoint Wireless Network 22 Description...
Страница 123: ...7 1 3 Troubleshooting Chart 113 Troubleshooting...
Страница 140: ...2009 EION Inc...