GB
- 40 -
The alarm LED (53) is lit up red
Fault
Possible cause
Remedy
“Hall-e
ff
ect sensor”
The robot lawn mo-
wer has come to a
stop right next to an
obstacle.
- The obstacle sensor has
been continually tripped for
10 seconds
Switch o
ff
the main switch (7) (OFF) and
place the robot lawn mower at a di
ff
erent
point in the mowing area. Switch on the main
switch (7) again (ON) and restart the mo-
wing operation on the control panel (2).
- Check whether the robot lawn mower
is blocked by an obstacle or jammed
between trees, bushes, etc. Remove the
obstacle or avoid this area.
- If this fault occurs frequently, check the
way in which the perimeter wire (18) has
been laid. Pay particular attention to tight
angles, corridors, fences, rocks, etc., and
adjust the layout of the perimeter wire (18)
if necessary.
The alarm LED (53)
fl
ashes red
Fault
Possible cause
Remedy
“Perimeter wire/sig-
nal fault”
The robot lawn mo-
wer goes round in
circles to search for
the perimeter signal
and ultimately co-
mes to a complete
stop.
- The robot lawn mower is out-
side the mowing area
- Perimeter wire (18) is not
properly connected
- Perimeter wire (18) is se-
vered
- No power supply
Switch o
ff
the main switch (7) (OFF) and
then switch it back on (ON) again. Re-start
the mowing operation on the control panel
(2).
- Make sure that the perimeter wire (18) has
been laid correctly and centrally under the
charging station (19)
- Check the position of the charging station
(19)
- Check that the robot lawn mower is inside
the mowing area.
- Check whether the LED indicator (21) on
the charging station (19) is lit up green.
- If the robot lawn mower repeatedly leaves
the mowing area at the same point, check
the area for high voltage cables. Change
the position of the perimeter wire (18).
- If the robot lawn mower leaves the mo-
wing area on a slope, avoid the area by
changing the position of the perimeter
wire (18).
Anl_GC_RM_500_SPK9.indb 40
Anl_GC_RM_500_SPK9.indb 40
16.02.2021 14:17:34
16.02.2021 14:17:34
Содержание GC-RM 500
Страница 195: ... 195 Anl_GC_RM_500_SPK9 indb 195 Anl_GC_RM_500_SPK9 indb 195 16 02 2021 14 17 55 16 02 2021 14 17 55 ...
Страница 196: ... 196 Anl_GC_RM_500_SPK9 indb 196 Anl_GC_RM_500_SPK9 indb 196 16 02 2021 14 17 55 16 02 2021 14 17 55 ...
Страница 197: ... 197 Anl_GC_RM_500_SPK9 indb 197 Anl_GC_RM_500_SPK9 indb 197 16 02 2021 14 17 55 16 02 2021 14 17 55 ...
Страница 198: ...EH 02 2021 03 Anl_GC_RM_500_SPK9 indb 198 Anl_GC_RM_500_SPK9 indb 198 16 02 2021 14 17 55 16 02 2021 14 17 55 ...