GB
- 22 -
6.2 Battery capacity indicator (Fig. 10/Item 9)
Press the battery capacity indicator switch (a).
The battery capacity indicator (9) shows the char-
ge status of the battery using 3 LEDs.
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED
fl
ashes:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.
6.3 On/O
ff
switch (Fig. 11)
•
Press the safety lock-off (5) in order to re-
lease the On/Off switch (3).
•
Actuate the On/Off switch (3).
•
Important! You can let go of the safety lock-
off (5) as soon as the On/Off switch (3) was
actuated.
•
To switch off the saw, let go of the On/Off
switch (3) again.
6.4 Making cuts with the bandsaw in hand-
guided mode (Fig. 12)
•
Set the adjustable handle (10) as described
in section 5.2.
•
Set the workpiece stop (13) as described in
section 5.3.
•
The material you want to cut must be clam-
ped securely.
•
Hold the machine firmly with both hands; use
the one hand on the handle (1) and the other
hand on the adjustable handle (10).
•
Take care to maintain a steady foothold.
•
Switch on the bandsaw as described in sec-
tion 6.3.
•
Move the bandsaw with its blade (15) in front
of the workpiece.
•
First place the workpiece stop (13) against
the workpiece and align the blade with the
cutting plane.
•
Now guide the bandsaw with a firm grip to the
workpiece and cut into it carefully.
•
Important! Do not exert excessive pressure
on the blade! This way you will obtain the
straightest possible cut while also prolonging
the life of the blade.
•
Do not cut any cross-sections larger than tho-
se described in section 4. Technical data.
•
Warning! If you are unable to cut through the
workpiece in a single pass, there will be a
greater risk of the blade getting jammed and
causing kickback!
6.5 Transport
•
Transport the machine only by lifting it by the
handle (1) or by the adjustable handle (10).
•
Never use the guards for handling or trans-
porting purposes.
7. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the mains power plug before star-
ting any cleaning work.
7.1 Cleaning
•
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
•
We recommend that you clean the device
immediately each time you have finished
using it.
•
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could at-
tack the plastic parts of the equipment. Ensu-
re that no water can seep into the device. The
ingress of water into an electric tool increases
the risk of an electric shock.
7.2 Carbon brushes
In case of excessive sparking, have the carbon
brushes checked only by a quali
fi
ed electrician.
Danger!
The carbon brushes should not be rep
laced by anyone but a quali
fi
ed electrician.
7.3 Maintenance
There are no parts inside the equipment which
require additional maintenance.
Anl_TE_MB_18_127_Li_SPK13.indb 22
Anl_TE_MB_18_127_Li_SPK13.indb 22
13.09.2022 14:38:58
13.09.2022 14:38:58