11. Troubleshooting guide
Faults
Cause
Remedy
Motor fails to start
up
- No mains voltage
- Pump rotor blocked -thermostat
switched off
- Check voltage
- Dismantle and clean pump
No intake
- Intake valve not in water
- Pump chamber without water con-
nection
- Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve) blocked
- Max. suction height exceeded
- Immerse intake valve in water
- Fill water into intake
- Make sure intake line is close
- Clean intake valve
- Clean strainer
- Check suction height
Inadequate delivery
rate
- Suction height too high
- Strainer dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
- Check suction height
- Clean strainer
- Place the suction hose at a deeper
level
- Clean pump and replace wearing
Thermostat swit-
ches pump off
- Motor overloaded - friction caused
by foreign substances too high
- Dismantle and clean pump. Prevent
intake of foreign substances (filter)
Anl_NHW-E_68_SPK7_1.indb 17
Anl_NHW-E_68_SPK7_1.indb 17
23.03.2021 13:25:24
23.03.2021 13:25:24
Содержание 41.731.96
Страница 108: ...BG 108 8 Anl_NHW E_68_SPK7_1 indb 108 Anl_NHW E_68_SPK7_1 indb 108 23 03 2021 13 25 30 23 03 2021 13 25 30...
Страница 113: ...BG 113 11 Anl_NHW E_68_SPK7_1 indb 113 Anl_NHW E_68_SPK7_1 indb 113 23 03 2021 13 25 30 23 03 2021 13 25 30...
Страница 118: ...118 Anl_NHW E_68_SPK7_1 indb 118 Anl_NHW E_68_SPK7_1 indb 118 23 03 2021 13 25 31 23 03 2021 13 25 31...
Страница 119: ...119 Anl_NHW E_68_SPK7_1 indb 119 Anl_NHW E_68_SPK7_1 indb 119 23 03 2021 13 25 31 23 03 2021 13 25 31...
Страница 120: ...EH 03 2021 01 Anl_NHW E_68_SPK7_1 indb 120 Anl_NHW E_68_SPK7_1 indb 120 23 03 2021 13 25 31 23 03 2021 13 25 31...