16
GB
Fault
Cause
Remedy
The motor does not start
Power failure
Motor circuit breaker has been
triggered
The safety switch is not making
contact
The switch for selecting the
direction of rotation is in its center
position.
Check the mains lead, plug and
fuse.
Press the Reset button (see point
6.5)
Insert the debris box correctly and
push the safety switch upwards
until it engages
Set the direction of rotation on the
switch
Material is not drawn in by the
shredder
The shredding blade is running in
reverse.
Material blockage in the filling
funnel
The shredding blade is jammed
Change the direction of rotation.
Change the direction of rotation
and pull the material out of the
funnel. Feed in thick branches
again so that the blade does not
immediately engage again in the
notches it previously cut.
Change the direction of rotation.
The blade will now release the
jammed material.
The material is not shredded
properly
The counter blade is not set
correctly.
Adjust the counter blade. See
section 6.8 on how to do so.
10. Troubleshooting
Anleitung_BG_RS_2540_CB_SPK1:_ 27.11.2008 14:23 Uhr Seite 16
Содержание 2540 CB
Страница 4: ...4 4 5 6 7 8 9 A 12 13 A 3 1 12 13 Anleitung_BG_RS_2540_CB_SPK1 _ 27 11 2008 14 23 Uhr Seite 4 ...
Страница 5: ...5 10 11 12 13 14 11 A 11 B C E D Anleitung_BG_RS_2540_CB_SPK1 _ 27 11 2008 14 23 Uhr Seite 5 ...
Страница 6: ...6 15 Anleitung_BG_RS_2540_CB_SPK1 _ 27 11 2008 14 23 Uhr Seite 6 ...
Страница 54: ...54 Anleitung_BG_RS_2540_CB_SPK1 _ 27 11 2008 14 24 Uhr Seite 54 ...
Страница 55: ...55 Anleitung_BG_RS_2540_CB_SPK1 _ 27 11 2008 14 24 Uhr Seite 55 ...