GB
- 15 -
4. Technical data
Mains voltage: ...................220-240 V ~ 50/60 Hz
Power input: ............................................ 1200 W
Tank volume: ..................................................18 l
Protection class: ...........................................II /
쓑
Weight: ................................................. ca. 3.5 kg
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Warning!
Always pull the power plug before making
adjustments to the equipment.
The appliance may only be connected to a shock-
proof socket.
5.1 Assembling the appliance
Fitting the appliance head (Fig. 2-5)
The appliance head (3) is fastened to the con-
tainer (7) by the locking hook (6). To remove the
appliance head (3), open the locking hook (6) and
remove the appliance head (3). When
fi
tting the
appliance head (3), make sure that the locking
hook (6) locks into place correctly.
Plug the vacuum tube (9) onto the end of the suc-
tion hose (10).
Fit the suction hose (10) onto the connection (8)
and turn until securely attached.
5.2 Fitting the
fi
lter
Notice!
Never use the ash vacuum without the
fi
lter!
Always ensure that the
fi
lters are perfectly secure.
Removing/
fi
tting the pleated
fi
lter (Fig. 6)
First undo the wing nut (12) and then remove the
pleated
fi
lter (11) and the
fi
lter cage (4) by pulling.
Assemble in reverse order. Check that the
fi
lter is
securely seated at all times.
Important!
The equipment comes with a safety switch (z)
which does not allow the equipment to be swit-
ched on when the pleated
fi
lter and the
fi
lter bas-
ket are not
fi
tted.
Fitting the coarse
fi
lter (Fig. 7)
Fit the coarse
fi
lter (13) as shown in Figure 7.
6. Operation
6.1 ON/OFF switch (Fig. 1/2)
Press the ON/OFF switch (2) to switch the equip-
ment ON and OFF.
6.2 Blowing
Connect the suction hose (10) to the blow con-
nector (5) of the ash vacuum cleaner.
6.3 Cleaning the appliance head
Clean the appliance regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plas-
tic parts in the appliance.
6.4 Cleaning the container
The container can be cleaned with a damp cloth
and some soft soap or under running water, de-
pending on the amount of dirt.
6.5 Cleaning the
fi
lter
Clean the
fi
lter basket (4), the pleated
fi
lter (11)
and the coarse
fi
lter (13), e.g. by tapping and
brushing or by blowing out with compressed air at
low pressure.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.