LC-XIP2000 Service
Manual Ver. A
17
Start
* Can’t make the green cross
target turn into black in
calibration procedure?
* Light pen or Baton (Pointer)
doesn’t work.
Yes
Troubleshooting
Clean battery’s
contact terminal or
replace battery
No
Check if
battery
contact OK
or battery
low
Replace Light Pen or Baton
unit and see if it works or
not
Yes
Clean it
No
Check if
CMOS
sensor
window
clean or
not
Yes
END
Refer to Owner’s Manual
for Software and
Hardware installation tips
and systems required
No
I. Built-in interactive smart function troubleshooting-2
Содержание LC-XIP2000
Страница 1: ...LC XIP2000 Service Manual Ver A 1 LC XIP2000 LCD projector Service Manual Version A Feb 14 2007...
Страница 4: ...LC XIP2000 Service Manual Ver A 4 Chapter 1 Trouble shooting...
Страница 6: ...Troubleshooting...
Страница 7: ...LC XIP2000 Service Manual Ver A 7 Troubleshooting LED Lamp Indicator...
Страница 18: ...LC XIP2000 Service Manual Ver A 18 Chapter 2 M B Firmware Download...
Страница 24: ...24 Chapter 3 Disassembly...
Страница 25: ...25 Disassembly...
Страница 27: ...27 Disassembly Screws List...
Страница 32: ...32 5 Key Pad Disassembly Disassembly A Take off 4 M3 5 screws...
Страница 33: ...33 6 IO Case Disassembly Disassembly A Take off 2 M3 8 screws...
Страница 37: ...37 10 Inlet Fan Disassembly Disassembly A Take off Fan no screws...
Страница 43: ...43 Disassembly 16 Take out Exhaust Duct A Unscrew BM3x8 2 pcs to take off Exhaust Duct module as below picture...
Страница 45: ...45 Disassembly 18 Take out Plate_MB_GND A Unscrew BM3x8 to disassemble Plate_MB_GND part...
Страница 48: ...LC XIP2000 Service Manual Ver A 48 Chapter 4 Service mode and Calibration...
Страница 56: ...LC XIP2000 Service Manual Ver A 56 Chapter 5 RS232 Command...
Страница 58: ...LC XIP2000 Service Manual Ver A 58 RS232 Command RS232 command...
Страница 59: ...LC XIP2000 Service Manual Ver A 59 RS232 Command RS232 command...
Страница 60: ...LC XIP2000 Service Manual Ver A 60 RS232 Command RS232 command...