LC-XG300/250_ Basic Serial Command Specifications   

                                                                                     

 

  

Ver. 

Rev.A 

Page 

 

3.13.  Characters for commands must be Capital (A - Z). 

 

4.  Functional Execution Command Table 

Command 

Item 

Command

Item 

C00 POWER 

ON 

C20 

BRIGHTNESS 

C01 

POWER OFF   

Quick Power OFF

 

C21 BRIGHTNESS 

C02 POWER 

OFF 

C22 

―――

 

C03 

―――

 

C23 

INPUT 2 VIDEO 

C04 

―――

 

C24 

INPUT 2 Y,Pb/Cb,Pr/Cr 

C05 INPUT 

C25 

INPUT 2 RGB 

C06 INPUT 

C26 

―――

 

C07 INPUT 

C27 

IMAGE 

C08 

NETWORK 

C28 

ON START Enable 

C09 

 

C29 

ON START Disable 

C0A 

VOLUME - 

C2A 

POWER MANAGEMENT READY

C0B 

SOUND MUTE ON 

C2B 

POWER MANAGEMENT OFF 

C0C 

SOUND MUTE OFF 

C2C 

―――

 

C0D VIDEO 

MUTE 

ON 

C2D 

―――

 

C0E VIDEO 

MUTE 

OFF 

C2E 

POWER MANAGEMENT SHUT DOWN

C0F 

SCREEN NORMAL SIZE

4

3

C2F 

―――

 

C10 

SCREEN WIDE SIZE

16

9

 

C30 D.ZOOM 

C11 

―――

 

C31 D.ZOOM 

C12 

―――

 

C32 INPUT 

AUTO 

C13 

―――

 

C33 

INPUT 3 VIDEO 

C14 

―――

 

C34 

INPUT 3 S-VIDEO 

C15 

―――

 

C35 

―――

 

C16 

―――

 

C36 

―――

 

C17 

―――

 

C37 

―――

 

C18 

―――

 

C38 

―――

 

C19 

―――

 

C39 

―――

 

C1A 

―――

 

C3A POINTER 

RIGHT 

C1B 

―――

 

C3B POINTER 

LEFT 

C1C 

MENU ON 

C3C 

POINTER UP 

C1D 

MENU OFF 

C3D 

POINTER DOWN 

C1E DISPLAY 

CLEAR 

C3E 

―――

 

C1F 

―――

 

C3F ENTER 

 

―――

  means no function. 

Содержание LC-XG250

Страница 1: ...BASIC SERIAL COMMAND SPECIFICATIONS LC XG300 250 Ver 0 01 TENTATIVE...

Страница 2: ...WER OFF Command 11 6 8 INPUT 1 Command 11 6 9 INPUT 2 Command 11 6 10 INPUT 3 Command 12 6 11 NETWORK Command 12 6 12 VOLUME Command 12 6 13 VOLUME Command 12 6 14 SOUND MUTE ON Command 12 6 15 SOUND...

Страница 3: ...FREEZE OFF Command 18 6 46 ZOOM Command 18 6 47 ZOOM Command 18 6 48 FOCUS Command 18 6 49 FOCUS Command 18 6 50 INPUT 1 Analog RGB Command 18 6 51 INPUT 1 SCART Command 19 6 52 INPUT 1 DVI PC Digital...

Страница 4: ...LC XG300 250_ Basic Serial Command Specifications Ver Rev A Page 3 7 8 Lamp Mode Read Command 25...

Страница 5: ...mputer 2 Serial Interface Specifications 2 1 Transfer Specifications Item Specifications Synchronous system Asynchronous Transmission Speed 9600 19200 Data Length 8 bit Parity N A Stop Bit 1 Flow Cont...

Страница 6: ...al time of 500ms at least after receiving a response 3 7 When a command is issued before receiving a response the function is not executed properly except when there is no Response for more than 5 sec...

Страница 7: ...E C08 NETWORK C28 ON START Enable C09 VOLUME C29 ON START Disable C0A VOLUME C2A POWER MANAGEMENT READY C0B SOUND MUTE ON C2B POWER MANAGEMENT OFF C0C SOUND MUTE OFF C2C C0D VIDEO MUTE ON C2D C0E VIDE...

Страница 8: ...C ADJ C4A FOCUS C8A PRESENTATION TIMER C4B FOCUS C8B C4C C8C C4D C8D C4E C8E KEYSTONE C4F C8F KEYSTONE C50 INPUT 1 Analog RGB C90 C51 INPUT 1 Scart C91 C52 INPUT 1 DVI PC Digital C92 C53 INPUT 1 DVI A...

Страница 9: ...ifications Ver Rev A Page 8 5 Status Read Command Table Command Item Memo CR0 Status Read CR1 Input Mode Read CR2 CR3 Corresponding Lamp Time Read CR4 Setting Read CR5 CR6 Temp Read CR7 Lamp Mode Read...

Страница 10: ...command pipelining Volume Zoom etc the performance is the same as that of the remote control 6 2 1 System issue any command every 100 ms 6 2 2 When receiving the appropriate command the function is e...

Страница 11: ...ted C01 POWER OFF C02 POWER OFF Countdown is terminated C46 ZOOM C47 ZOOM C4A FOCUS C4B FOCUS C5D LENS SHIFT UP C5E LENS SHIFT DOWN C5F LENS SHIFT LEFT C60 LENS SHIFT RIGHT Cooling Down in process NON...

Страница 12: ...function as ON STAND BY button of the projector and remote control Once this command is sent Power OFF is displayed If this command is sent again while it is displayed Power OFF is executed When sendi...

Страница 13: ...ptable ACK CR Response Unacceptable CR 6 12 VOLUME Command Command C09 CR Detail Volume Up This command operates the same way as VOLUME button of the projector and remote control Acceptable ACK CR Res...

Страница 14: ...for No Show OFF Acceptable ACK CR Response Unacceptable CR 6 17 VIDEO MUTE OFF Command Command C0E CR Detail Video Mute OFF This command works the same way as NO SHOW button of remote control for No...

Страница 15: ...esponse Unacceptable CR 6 23 BRIGHTNESS Command Command C20 CR Detail Brightness of User Control 1 Acceptable ACK CR Response Unacceptable CR 6 24 BRIGHTNESS Command Command C21 CR Detail Brightness o...

Страница 16: ...d retained regardless of Power OFF ON Acceptable ACK CR Response Unacceptable CR 6 30 ON START Cancel Command Command C29 CR Detail Disable Power ON Start This status is stored in EEPROM and retained...

Страница 17: ...remote control Acceptable ACK CR Response Unacceptable CR 6 35 D ZOOM Command Command C31 CR Detail Enter Digital Zoom mode and reduce image size This command works the same way as D ZOOM button of th...

Страница 18: ...mand Command C3C CR Detail Move up the Pointer of On Screen Display This command operates the same way as button of the projector Acceptable ACK CR Response Unacceptable CR 6 42 POINTER DOWN Command C...

Страница 19: ...d image size This command works the same way as ZOOM button of the projector Acceptable ACK CR Response Unacceptable CR 6 48 FOCUS Command Command C4A CR Detail Adjust on screen focus by making focal...

Страница 20: ...cceptable CR 6 53 INPUT 1 DVI AV HDCP Command Command C53 CR Detail Select DVI AV HDCP input in Input 1 Acceptable ACK CR Response Unacceptable CR 6 54 LENS SHIFT UP Command Command C5D CR Detail Move...

Страница 21: ...MER Command Command C8A CR Detail Execute Presentation Timer This command works the same way as P TIMER button of the remote control Acceptable ACK CR Response Unacceptable CR 6 60 KEYSTONE Command Co...

Страница 22: ...ceives the appropriate command it returns a character line as the required data Required Data CR Required Data A character line See Basic Status Read Command Table 7 1 3 When the received data cannot...

Страница 23: ...us is Standby Status Read Commands are always acceptable but Functional Execution Commands are not acceptable except POWER ON Command 7 3 3 40 CR Status Countdown in process When Display in Setting Me...

Страница 24: ...e status turns to Standby because of abnormal temperature This status maintains until next operation is done When Power On is executed the information of temperature anomaly is canceled and normal ope...

Страница 25: ...nd Command CR1 CR Detail Get the selected Input No Acceptable 1 CR 1 1 Input 1 is selected 2 Input 2 is selected 3 Input 3 is selected 4 Input 4 is selected Response Unacceptable CR 7 5 Lamp Time Read...

Страница 26: ...the temperature goes down to the first character becomes instead of a space like 05 5 CR When no temperature data can be returned due to hardware problems the first character becomes E like E00 0 CR...

Отзывы: