LC-XG300/250_ Basic Serial Command Specifications
Ver.
Rev.A
Page
9
6. Functional
Execution
Command
6.1. Format
6.5.1. PC issues a command in format as below.
“C” COMMAND [CR]
Command: two characters (See Basic Functional Execution Command Table)
6.5.2. A projector changes received data to decode and returns a result after being ready to receive
next command.
[ACK]
[
CR
]:(
0x06
、
0x0D
)
When received Functional Execution Commands.
6.5.3.
“
?
”
[
CR
]:
When the received data cannot be decoded.
6.2. Command
Pipelining
When some functions need the command pipelining (/-, Zoom +/-, etc), the performance is
the same as that of the remote control;
6.2.1. System: issue any command every 100 ms.
6.2.2. When receiving the appropriate command, the function is executed for 120 ms from the
moment.
6.2.3. When receiving the same command continuously within 120 ms, the function is executed for
another 120 ms from the moment.
6.2.4. When there is no incoming command after 120 ms, the execution of pipelining is stopped.
6.2.5. When the projector receives other incoming commands within 120ms, the execution of
pipelining is stopped.
6.3. Transfer
Example
Switch the projector to video mode with Basic Command.
Command
PC
→
Projector
C 0 7 CR
Projector
→
PC
ACK
CR
Processing
(
A few ms
〜
5s
)