-44-
Electrical Adjustment
,
Gamma shipment adjustment
Software
PROJECTOR SERVICE TOOL v4.20
Use the software to obtain the proper gray scale. See the
further information of the software instruction manual.
n
Common Voltage adjustment
Input mode
Computer mode (Input 1 RGB)
Input signal
50%-RGB pattern computer signals
or 16-step gray scale computer sig-
nal
1. Enter the service mode.
2. Select Group "
101
", No. "
4
" and then change data val-
ue from "
2
" to "
0
" to reduce the panel frequency.
3. Change data value to obtain
the minimum flicker
for
each color on screen.
group No.
adjustment
100 - 11
for red flicker
100 - 9
for green flicker
100 - 10
for blue flicker
4. Select Group "
101
", No. "
4
" and then change data val-
ue from "
0
" to "
2
".
⁄1
Wind Sensor calibration
1. Enter the service mode.
2. Select group no. “
240
” and item no. “
2
”. Confirm the
Data value is “
1
”.
0: Wind sensor function Disable
1: Wind sensor function Enable
3. Select group no. “
240
” and item no. “
0
”.
4. To start the adjustment, change data value from “
0
”
to “
1
”. After the auto-calibration completed, "OK" will
appear on the screen.
IMPORTANT
Before taking this adjustment, you need to replace the air
filter with new one or scroll up the filter sheet and make
sure the cabinet top, filter cover and filter cartridge are
securely installed.
.
White Balance adjustment
Input mode
Computer mode (Input 1 RGB)
Input signal
16-step gray scale computer signal
1. Enter the service mode.
2. Change data value to obtain the proper white balance.
group No.
adjustment
100 - 5
red color balance
100 - 4
Blue color balance
m
Panel Type Check and Setting
* Before setting, you need to check which type of LCD pan-
el is placed on the projector according to the item "LCD
Panel/Prism Ass'y removal" in the chapter "Optical Parts
Disassembly".
1. Enter the service mode.
2. Panel Type Check
Select group no. “
290
”, item no. “
0
”. Check the data
value as follows;
Data value: 0
For L-Type of LCD Panel
Data value: 20
For R-Type of LCD panel
If the mounted LCD panel type and set Panel mode are
differ, take the step below.
3. Panel Type Mode Setting
Select group no. “
290
”, item no. “
1
” and change data
value from 10 to 0 or 20 depending on your LCD Panel
type. When the data value reaches 0 or 20, it returns
to 10 quickly. The gamma-characteristics changes ac-
cording to your selection.
⁄0
Color Shading Correction adjustment
Software
PROJECTOR SERVICE TOOL v4.20
Use the software to correct the color shading of the
screen. See the further information of the software in-
struction manual.
The color shading correction adjustment for this model
should be performed with the whole-gray patterns speci-
fied as below.
8-input patterns:
5% gray, 10% gray, 15% gray, 20% gray,
30% gray, 50% gray, 75% gray, 95% gray
Содержание Conference LC-WUL100
Страница 91: ...91 IC Block Diagrams LV49152V Audio Output IC001 FA5502 P F Control IC601...
Страница 93: ...93 IC Block Diagrams BA7078 Sync Separator IC1011 CXA7010 S H IC1501 IC501 IC2501 SH INPUT ADJ DAC ADJ DAC...
Страница 94: ...94 IC Block Diagrams ISL51002 A D Converter IC201 M62393 DAC IC7801...
Страница 95: ...95 IC Block Diagrams NJM2671 Motor Controller IC5541 NJW1156 Audio Selector IC5001...
Страница 96: ...96 IC Block Diagrams PIC18F67 PIC IC8801 PW392 Scaler IC301...
Страница 97: ...97 IC Block Diagrams PW610 Keystone IC2301 STR A6079 Power switching IC603...
Страница 98: ...98 IC Block Diagrams TE7783 I O Expander IC4801 STR Z2156 Power switching IC651...
Страница 99: ...99 IC Block Diagrams THS7347 3 CH Analog SW IC5231 IC5251 IC5271 LIS331 3600 G Sensor IC3850...
Страница 100: ...100 IC Block Diagrams TB6608 IRIS Driver IC601...
Страница 107: ...107 Parts Location Diagrams KH2 WUL10000 KH2 WUL100L00 Mirror B assembly S07 S07 S07 L11 M11...
Страница 162: ...KH2B KH2BL December 2010 Printed in Japan 2010 Eiki Internatinal Inc A key to better communications...