-178-
Troubleshooting
error
error
code
error infomation
(See Powe Failure Detection Tree)
error
code
error infomation
(See Powe Failure Detection Tree)
Normal
0
-
Power Failure
1000
AV,
AV
1018
DC,
FAN4
1001
MOTHR,
MOTHER
1019
DC,
FAN5
1002
MAIN,
AD
1020
DC,
FAN9
1003
MAIN,
F FPGA
1021
DC,
FAN8
1004
MAIN,
TH
1022
DC,
FAN7
1005
MAIN,
PIC
1023
DC,
FAN6
1006
RS232C,
LAN
1024
ERR,
PRESSURE
1007
MAIN,
25V
1025
ERR,
FIL_DET
1008
MAIN,
I/O
1026
ERR,
FIL_MTR
1009
MAIN,
S16V
1027
ERR,
SHUT_MTR
1010
MAIN,
S3.3V
1028
PFC.
PFC1
1011
MAIN,
S12V
1029
PFC.
PFC2
1012
MAIN,
KEYSTONE
1030
PFC.
PFC3
1013
MAIN,
GAMMA
1031
PFC.
PFC4
1014
MAIN,
S-5V
1032
ERR,
IIC_DATA
1015
MAIN,
S5V
1033
SLOT3,
1016
DC,
FAN1
1034
SLOT4,
1017
DC,
FAN2+3
Temperature Error
2000
Temperature Error detected on the Sensor (IC8811) (Arround the Intake Duct)
2001
Error of the detection (IC8811 communication error)
2101
Error of the detection (IC8851 communication error)
2200
Temperature Error detected on the Sensors (IC8811, IC8851) (Temp. error between internal and external)
Lamp Error
3000
Lamp1 fails on
3001
Lamp1 goes out
3002
Communication Error on Lamp1
3100
Lamp2 fails on
3101
Lamp2 goes out
3102
Communication Error on Lamp2
3200
Lamp3 fails on
3201
Lamp3 goes out
3202
Communication Error on Lamp3
3300
Lamp4 fails on
3301
Lamp4 goes out
3302
Communication Error on Lamp4
System Error
4000
Config Error (FPGA, AV, Mother, Ye)
4001
Config Error (FPGA SW, LVDS)
Filter Error
6000
Clogged filter
Error history log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and
select Group No. "
220
" and Item No. "
0
" to "
49
". The error
code is displayed on the Data column. The description of
the error code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
91
0
1
2
3
:
:
49
✻
<- Latest Error
✻
✻
✻
:
:
✻
How to reset the error history log
1. Enter the Service Mode, and select Group No. "
220
" and Item No. "
50
".
2 The history log will be reset when the Data Value is set to "
10
". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service adjustment menu operation".
Содержание 1 122 511 01
Страница 189: ...189 IC Block Diagrams CXD3550 Gamma IC401 CXA7010 S H IC501 IC1501 IC2501 IC1501 IC1551 IC2551...
Страница 190: ...190 IC Block Diagrams FA5501 PFC IC1601 IC1651 HIN202 RS232C Driver IC3801...
Страница 192: ...192 IC Block Diagrams M62393 DAC IC7802 IC5691 IC5692 PIC17F67 Network IC8301...
Страница 193: ...193 IC Block Diagrams TE7783 I O Expander IC1801...
Страница 201: ...201 Parts Location Diagrams KL8 HDT200000 M01 3 M01 4 Lens shift assembly M01 1 M01 2 M01 2...
Страница 206: ...206 Parts Location Diagrams KL8 HDT200000 Optical filter LC CS L18 Integrator assembly S06 L08 S06...
Страница 207: ...207 Parts Location Diagrams KL8 HDT200000 MIrror R assembly S06 L15 Integrator PBS assembly S06 L08 S06 L19 S06 S06...
Страница 208: ...208 Parts Location Diagrams KL8 HDT200000 Relay lens OUT assembly L06 S06 S06...
Страница 209: ...209 Parts Location Diagrams KL8 HDT200000 L09 L07 In the Optical unit L14 L14 L05 L21 L13 L11 L20 L10 L12...
Страница 210: ...210 Parts Location Diagrams KL8 HDT200000 Optical filters assembly Mirror assembly L15 L15 L17 L16...
Страница 278: ...KL8B Mar 2011 Japan 2011 Eiki Internatinal Inc A key to better communications...
Страница 298: ...A18 SCH_KL8A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D E F G H I J K L A B C D E F G H I J K L NO DATA...