7.Operation 

7.1 

 

Charge

 

Displays the present remaining amount of the 

battery. 

Less than 15% remains, please charge. 

NOTE

 

 

If the power if less than 15%, must be 

recharged within 30 days, otherwise 

the battery will be damaged.

 

 

Charging indication appears on the screen, and 

flashes slowly , when battery is fully charged or 

in a state near full charge, the flash will stop 

Fully charged will take about 4 hours, 

depending on residual battery power and 

battery state. 

It can be recharged 300-500 times, depending 

on the operating conditions of the device. 

NOTE

 

 

When changing, other function will 

forcibly stop, take from charge base, 

press main switch, the last function 

will recall.

 

WARNING

 

 

Do not change the battery, only trained technician or 

distributor can change the battery, the electronic parts will 

be damaged if use a wrong battery or install with a wrong 

way.

 

 
 
 
 
 
 
 

Содержание CuringPen

Страница 1: ...s CuringPen LED Curing Light USER MANUAL Changzhou Sifary Medical Technology Co...

Страница 2: ......

Страница 3: ...CuringPen 8 4 1 Install the light source head 8 4 2 Install the disposable sleeve 8 4 3 Install the protective light shield 8 4 4 Charging 10 5 Use Interface 11 5 1 Panel key 11 6 Setting 12 6 1 Selec...

Страница 4: ...si tutaj pojawi B d U yj karty Narz dzia g wn e aby zastosowa 1 do tekstu kt ry ma si tutaj pojawi Page 4 30 1 Scope of CuringPen 1 1 Parts Identification 5 1 2 3 4 6 1Light source head 2 Protective l...

Страница 5: ...nts and accessories Handpiece 1pcs ORDER CODE 6551003 Light source head 1pcs ORDER CODE 6551001 Disposable sleeve 100pcs ORDER CODE 6542002 Adapter 1pcs ORDER CODE 6516001 Charging base 1pcs ORDER COD...

Страница 6: ...atient NOTE Additional information explanation of operation and performance SN Serial number REF Catalogue number Manufacturer Date of manufacture Safety class II device Type B applied part Direct cur...

Страница 7: ...act with any type of liquids 2 Do not expose the device to direct or indirect heat sources The device must be operated and stored in a safe environment 3 The device requires special precautions with r...

Страница 8: ...light source head and the handpiece pull it gently to make sure the connection is good Make sure the assembly is connected properly otherwise might cause unexpected fault even hurt the patients 4 2 In...

Страница 9: ...B d U yj karty Narz dzia g wne aby zastosowa 1 do tekstu kt ry ma si tutaj pojawi B d U yj karty Narz dzia g wne aby zastosowa 1 do tekstu kt ry ma si tutaj pojawi Page 9 30...

Страница 10: ...to a power outlet the Power LED on charge base will light up green NOTE Only the original adapter could be used Put the handpiece all the way into the charge base the charge state will show on the scr...

Страница 11: ...S Setting key Turn Power On Press more than 0 5 seconds to turn on the instrument Memory Change Press setting key during standby state Turn Power Off Long press to turn power off Advanced setting Duri...

Страница 12: ...Long Press S to enter the light intensity setting menu then press S to change or press main switch to confirm and exit On the light intensity setting menu long press S to enter the time setting menu N...

Страница 13: ...ess to change setting press S to enter the next setting Volume volume setting mode Volume mid In the volume setting menu press S to select different settings It can be set to Off low mid or high Press...

Страница 14: ...n appears on the screen and flashes slowly when battery is fully charged or in a state near full charge the flash will stop Fully charged will take about 4 hours depending on residual battery power an...

Страница 15: ...tensity output There is a beep every 5s while working and the output is automatically turned off after the countdown ends WARNING When the device is working do not directly illuminate the eyes otherwi...

Страница 16: ...n the device is in standby mode it will automatically shut down when it reaches the set time The factory default setting is 5 minutes WARNING Before using please try it outside the oral cavity to ensu...

Страница 17: ...cm 1500mW cm or 1000mW cm Wavelength 385nm 515nm When pressed the setting light intensity is output immediately and the sound is prompted every 5 seconds 100 light intensity Time RAMP Ramp Mode Light...

Страница 18: ...ery 1 second prompting the sound every 5 seconds 100 light intensity Time Detect Detecting mode Light intensity 600mW cm Wavelength 385nm 410nm 100 Light intensity Time When pressed he setting light i...

Страница 19: ...surfaces with a cloth lightly moistened with Ethanol for Disinfection Ethanol 70 to 80vol at least 2min repeat for 5 times WARNING Do not use anything except Ethanol for Disinfection Ethanol 70 to 80...

Страница 20: ...too low Charge it immediately Fault Blue Error Blue LED broken contact your distributor Fault Blue Overload Blue LED overload contact your distributor Fault Violet Error Violet LED broken contact your...

Страница 21: ...ED does not light up when charging Use a wrong adapter Use the original adapter There is no electricity in the outlet Check the connection The adapter is not connected Check the connection the handpie...

Страница 22: ...B d U yj karty Narz dzia g wne aby zastosowa 1 do tekstu kt ry ma si tutaj pojawi B d U yj karty Narz dzia g wne aby zastosowa 1 do tekstu kt ry ma si tutaj pojawi Page 22 30...

Страница 23: ...1600mAh 10 Charger power supply AC 100 240 V 10 Charger power output 5V 1A Power Frequency 50 60Hz 10 Charger nominal power input 5VA Light intensity 2300mW cm 1500mW cm 1000mW cm 600 mW cm Wavelength...

Страница 24: ...ssions CISPR 11 Class B The CuringPen is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that suppl...

Страница 25: ...arth 0 5kV 1kV 2kV Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply lines IEC 61000 4 11 0 UT...

Страница 26: ...ringPen is intended for use in the electromagnetic environment specified below The customer or the user of the CuringPen should assure that it is used in such an environment Immunity test IEC 60601 te...

Страница 27: ...and or systems are used When they are used in close proximity to medical equipment and or systems the medical equipment and or systems basic safety and essential performance may be affected The Curing...

Страница 28: ...Page 28 30 930 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulati on 18Hz 1720 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulati on 217Hz 2 0 3 28 1845 1970 2450 2400...

Страница 29: ...he lithium batteries are disposed as special refuse Please deal with them according to the local environmental protection laws and regulation Rights All rights of modifying the product are reserved to...

Страница 30: ...a 1 do tekstu kt ry ma si tutaj pojawi Page 30 30 Changzhou Sifary Medcial Technology Co Ltd Add NO 99 Qingyang Road Xuejia County Xinbei District Changzhou City 213000 Jiangsu China Tel 86 0519 85962...

Отзывы: