In the event of a power interruption, release the locking switch by
pressing the on/off switch. This will prevent the power tool from
restarting unintentionally (risk of injury).
Do not use the power tool in a stand.
When working with this machine wear ear protectors, goggles,
dust mask, protective gloves and protective boots.
During use, always hold the machine with both hands and maintain a
safe standing position. Start up and run down the machine in the
mixing container only. Pay attention to the reaction moment of the
machine.
For further safety instructions, please refer to the enclosure.
Electrical Connection
Before starting the machine check the correspondence between voltage
and frequency according to the data mentioned on the identification plate.
Voltage differences from + 6 % and – 10 % are allowed.
The mixer is made in protection class II.
Only use extension cables with a sufficient cross-section. A cross-section
which is too small could lead to an excessive power loss and to an
overheating of motor and cable.
Recommended minimum cross sections and maximum cable lengths
Mains voltage
Cross section in sq. mm
1.5
2.5
110V
20 m
40 m
230V
50 m
80 m
Tool Change
Attention!
Before any work on the tool, disconnect the plug from the mains!
When inserting the tool, you could catch your hands. For this reason,
always wear protective gloves for changing the tool.
The work spindle of the machine has a M 14 - internal thread. Keep
threads and front surface clean.
Please hold up with a jaw wrench 22 to remove the stirring rod.