Fitting the handle
Please fit the handle provided before the machine is started up for the first
time:
Additional handle for hold-down device:
First, check the correspondence between voltage and frequency against
the data mentioned on the identification plate. Voltage differences from
+ 6% to – 10% are allowed.
The
EFB 152 PX
is made in protection class I.
For protection purposes, the machine can only be run with a GFCI. For this
reason, the
EFB 152 PX
is standard delivered with an integrated PRCD
protective switch which can be used for a ground socket
!
Attention!
The PRCD protective switch must not lay down in water.
PRCD protective switches must not be used to switch the
tool on and off.
Before starting your work, check the proper function by
pressing the TEST button
.
Only use 3-wire extension cords with a sufficient cross-section. A cross-
section which is too small might cause a considerable drop in performance
and an overheating of machine and cable.
Water Supply
The
EFB 152 PX
has a water circulation by means
of a pump. Before you start working with the
machine, fill the pan with water until the suction
connection is competely covered. This is the only
way to assure a proper operation.
Only have the machine run with enough water
supply. Dry-drilling could damage the seals
Electrical Connection
Screw this into the hold-down device and
tighten it with an SW 17 open-ended spanner.