FP-5L

RS-232 (5-volt) Option

1014031

10/14/03

1. General Description

1. General Description

1. General Description

1. General Description

1. General Description

The RS-232 (5-volt) option transmits serial RS-232 (5-volt) data on the white/green wire (pin 15) of the FP-
5L.  The serial data transmitted is the same as that shown on the digital display when displaying Fuel Flow (in
gal/hr), Fuel Remaining (in gal/hr) and the AUX channel.  The transmited format is compatable with the
MUX-8A and if the transmitted signal is inverted, it may be connected directly to a P.C.  The serial data is
transmitted in a comma delimited format, suitable for importing into most spreadsheet and data base programs.
The transmited format for this RS-232 Option is not compatable with GPS units.  The received format was not
changed and is compatable with GPS units.

2. Instrument Operation

2. Instrument Operation

2. Instrument Operation

2. Instrument Operation

2. Instrument Operation

Although the RS-232 (5-volt) option does not affect the operation of the FP-5L, the operation of the FP-5L can
affect the transmission rate.  If the FP-5L is placed in any programming mode the transmition of data will stop
until the FP-5L is returned to normal operation.  Also, the "GPS Receive Format" and the "Display Update
Time" will affect the Baud Rate or Transmit Rate (see Power-up Programming).  The "GPS Transmit Format"
setting has no effect on the RS-232 (5-volt) output.

3.

3.

3.

3.

3.      T

T

T

T

Transmit Specification:

ransmit Specification:

ransmit Specification:

ransmit Specification:

ransmit Specification:

* Baud Rate:

9600 baud when "GPS Receive Format" is set to "In1" (see Power-up Programming).
(9600 is the only baud rate that will interface with the MUX-8A)
1200 baud when "GPS Receive Format" is set to "In2" (see Power-up Programming).
4800 baud when "GPS Receive Format" is set to "In3" (see Power-up Programming).

* Data Bits:

8

* Start Bit:

1 (Logic Low)

* Stop Bit:

1 (Logic High 5-volts)

* Parity:

None

* Transmit Rate: 1.5 sec. for "Display Update Time" set to "UP1" (see Power-up Programming).
                            0.5 sec. for "Display Update Time" set to "UP2" (see Power-up Programming).

4.

4.

4.

4.

4.      T

T

T

T

Transmit F

ransmit F

ransmit F

ransmit F

ransmit Format

ormat

ormat

ormat

ormat

The FP-5L transmits the following record:

FP,FFF.F,RRR.R,AAAACrLf

FP

Instrument identifier.

,

A comma separates data fields.

FFF.F

Fuel Flow in gal/hr.

RRR.R Fuel Remaining in gal/hr.
AAAA AUX Channel Data
Cr

Carriage return (0Dh)

Lf

Line feed (0Ah)

5. Hook-Up

5. Hook-Up

5. Hook-Up

5. Hook-Up

5. Hook-Up

The white/green wire originally used to upload data to a GPS is now used to output data to the MUX-8A or to a
PC via the MUX-8A.  Set the "GPS Receive Format to "In3" (9600 baud) on the FP-5L to interface with the
MUX-8A.

Содержание MUX-8A

Страница 1: ...ctronics International Inc Electronics International Inc Electronics International Inc 63296 Powell Butte Hwy Bend OR 97701 541 318 6060 Buy EI com 63296 Powell Butte Hwy Bend OR 97701 541 318 6060 Bu...

Страница 2: ......

Страница 3: ...ft delayyourinstallationoraffecttheoperationofyourinstrument YouMust Must Must Must Must readthismanualpriortoinstallingyourinstrument readthismanualpriortoinstallingyourinstrument readthismanualprior...

Страница 4: ......

Страница 5: ...ck ormation and Initial Check ormation and Initial Checkout out out out out 9 9 9 9 9 B Mount the MUX 8A Control Switch B Mount the MUX 8A Control Switch B Mount the MUX 8A Control Switch B Mount the...

Страница 6: ...oudonotagreetoandacceptthetermsofthiswarranty youmayreturntheproductfora Ifyoudonotagreetoandacceptthetermsofthiswarranty youmayreturntheproductfora refund refund refund refund refund ThisWarrantyisma...

Страница 7: ...e Data Recorder can be enabled or disabled with the DIP switchs found in an open ing on the side of the Data Recorder s black box The Data Recorder scans the enabled input channels formats the incomin...

Страница 8: ...s recorded In the BURST mode data is being recorded continuously and the Record Light will be on all the time Data Storage Data Storage Data Storage Data Storage Data Storage Data is stored into the D...

Страница 9: ...ry minute regardless of the Storage Time Interval setting The moment the Event Warning Line goes to a high level a recording is initiated and OFF will be stored in the Event Warning field If this line...

Страница 10: ...Data Recorder performs this logic for each channel B Enable Disable the Time out Period If the Time out feature is set for 30 seconds the Data Recorder will monitor an enabled channel for 30 seconds I...

Страница 11: ...s screen will say Download Completed Pushing the Control Switch to the BURST position will stop the download and start the processing of data 4 When finished turn off the aircraft power and exit the D...

Страница 12: ...Downloaded data comes from the Data Recorder s internal memory and represents data that was recorded from instruments at an earlier date As the Data Recorder scans each enabled channel it transmits a...

Страница 13: ...MA TSO approved manufacturing facility If the installer determines that installing this device is a minor alteration he she must note it as such in the aircraft log book Example 2 6 00 Installed Elec...

Страница 14: ...ector The RS 232 Connector Locate the RS 232 connector in the MUX 8A kit Drill a 1 4 hole in the aircraft instrument panel for the RS 232 connector and mount the connector from behind the aircraft ins...

Страница 15: ...he MUX 8A Wiring Dia gram at the back of this manual MUX 8 9 Pin Male Connector Wire Color Channel Connect to Brown 1 E I Inst RS 232 5V Line Red 2 E I Inst RS 232 5V Line Orange 3 E I Inst RS 232 5V...

Страница 16: ...ectingtheEventWarningLineto ConnectingtheEventWarningLineto ConnectingtheEventWarningLineto morethanoneE I Instrument morethanoneE I Instrument morethanoneE I Instrument morethanoneE I Instrument more...

Страница 17: ...n The Record Light should go out in 10 seconds or less this time depends on the total Transmit Rate for all the instruments connected to the MUX 8A If the Record Light is staying on for approximately...

Страница 18: ...rval setting 1 3 or 6 min A ground on the Event Warning Line will generate an ON in the MUX 8A transmitted record and the Storage Interval will be one minute A transition from open to ground will gene...

Страница 19: ...To GPS 8 GPS only To Ground R e d Black Blue White Red White Yellow Record Light Control Switch 9 Pin Male Connector 9 Pin Female Connector To 12 or 24 Volt Bus via the 1 amp fuse used above Brown Br...

Страница 20: ...Operation 2 Instrument Operation The RS 232 5 volt output does not affect the operation of the R 1 3 3 3 3 3 T T T T Transmit Specifications ransmit Specifications ransmit Specifications ransmit Speci...

Страница 21: ...f GPS Instrument identifier A comma separates data fields A Present Latitude s dd mmhh s sign N for north S for south dd degrees mm minutes hh hundredths of minutes B Present Longitude s dd mmhh s sig...

Страница 22: ...peration The RS 232 5 volt option does not affect the operation of the R 1 See the R 1 Operating and Installation Instructions for R 1 operating information 3 3 3 3 3 T T T T Transmit Specifications r...

Страница 23: ...Instrument Operation The RS 232 5 volt option does not affect the operation of the M 1 See the M 1 Operating and Installation Instructions for M 1 operating information 3 3 3 3 3 T T T T Transmit Spe...

Страница 24: ...t option does not affect the operation of the OPT 1 See the OPT 1 Operating and Installation Instructions for OPT 1 operating information 3 3 3 3 3 T T T T Transmit Specifications ransmit Specificatio...

Страница 25: ...Format and the Display Update Time will affect the Baud Rate or Transmit Rate see Power up Programming The GPS Transmit Format setting has no effect on the RS 232 5 volt output 3 3 3 3 3 T T T T Trans...

Страница 26: ...ASC 5A can affect the transmission rate If the ASC 5A is placed in any programming mode the transmition of data will stop until the ASC 5A is returned to normal operation 3 3 3 3 3 T T T T Transmit Sp...

Страница 27: ...he RS 232 5 volt option allows the Scan Rate to be set between 0 and 9 seconds For a given Scan Rate the US 8A operates as follows 0 Scan Rate All the limits are disabled the US 8A continuously scans...

Страница 28: ...entifier A comma separates data fields L1 Left channel 1 reading 999 to 1999 F Other left channels are L2 L3 etc R1 Right channel 1 reading 999 to 1999 F Other right channels are R2 R3 etc Cr Carriage...

Отзывы: