1. Introduction

 
This leaflet describes the installation of the Ei170RF / Ei171RF and its integration into a total RF Fire 
Alarm System, incorporating a choice of RF Smoke/CO/Heat Alarms and Accessories.
Note: It is essential that the Ei170RF / Ei171RF is connected to the mains to preserve its one-week 

battery standby. Leaving the unit operating without mains connected will completely deplete the 
battery and possibly damage it. (If the Ei170RF / Ei171RF is not being used for a prolonged period 
and cannot be left plugged in to the mains, then disconnect the battery).
Location
The Strobe Module should normally be fixed such that the internal strobe light can be seen from the bed, 
and the vibration pad can be placed under the mattress or pillow. It has to be powered from the mains 
(100-240VAC/50-60Hz) so a suitable socket must be available to which it can be permanently connected.
The back-up battery in the Strobe Module must not be exposed to excessive heat such as sunshine, 
heaters or fires.
The associated RF Alarms and Accessories must be located and installed as described in their own 
instruction leaflets.
Note: If installing the Ei170RF / Ei171RF in a system containing CO Alarms, we recommend installing 

an Ei450 to determine the source of the alarm.

2. Installation

Strobe Module Ei170RF / Ei171RF
The battery must first be installed in the Strobe Module. Open the rear compartment by squeezing 
together the two latches as shown in Figure 1b, and lifting the cover off.

Plug the battery into the socket at the rear of the battery compartment as shown in Figure 2 (while 
holding the small latch on the battery plug, open). Place the battery in the compartment ensuring the 
notch in the battery is used to leave clearance for the plug and sockets (see Figure 3).

The Strobe Module can be left on a table or permanently fixed to the wall using the screws and plastic 
plugs enclosed. Use the drilling template (Figure 5).

Squeeze
Here

Squeeze

Here

Battery
Cover

Auxillary

Sockets

Mounting

Screw

Holes

Wire

Channels

for mains lead &
Vibration Pad
(and accessories
if required)

Model: Ei170R

For use with RadioLINK Smoke Alarms

RadioLINK Fire Alarm Panel for

Deaf & Hard of Hearing

1. Connect battery plug & then plug in mains.
2. After installation, house code system by pressing

house code switch with a small screwdriver or simila

Vibration Pad (Ei170RF)

Conversion Jack (Ei171RF)

Figure 1a

Figure 1b

Squeeze as shown to open

battery compartment

Содержание RadioLINK Ei170RF

Страница 1: ...LINK Alarm System with Strobe Only Note At least one RF Smoke CO Heat Alarm is required to make the Ei170RF Ei171RF Alarm operational This is not supplied with the Ei170RF Ei171RF and must be obtained separately Important Read these instructions together with those from the separate RF Smoke CO Heat Alarms and accessories before installation All instruction leaflets must be left with the end user ...

Страница 2: ...s Note If installing the Ei170RF Ei171RF in a system containing CO Alarms we recommend installing an Ei450 to determine the source of the alarm 2 Installation Strobe Module Ei170RF Ei171RF The battery must first be installed in the Strobe Module Open the rear compartment by squeezing together the two latches as shown in Figure 1b and lifting the cover off Plug the battery into the socket at the re...

Страница 3: ...screws accurately The screws large heads should be screwed into the wall leaving a gap of approximately 4mm 0 15in under the head Fit the keyhole slots on the back of the Strobe Module over the screw heads and slide the panel down vertically into position Battery Battery Plug Latch Figure 2 Battery Clearance Notch Figure 3 Shows battery orientation Dress the battery leads as shown replace the batt...

Страница 4: ... code all other RF Alarms and devices in the system Consult the instruction manuals on how to house code the Alarms and devices It is essential that each individual Alarm device is put into House Code mode in its final location 3 Check the number of flashes on the Ei170RF Ei171RF and on every other device They should correspond to the total number of devices in your system A system with 3 Smoke Al...

Страница 5: ...5 Mains Indicator Green mains disconnected amber flash 4 seconds RadioLINK Indicator Blue House Code Button Alarm Indicator Red Fault Indicator Amber Test Button Strobe TEST ALARM FAULT Figure 4 ...

Страница 6: ...battery is almost depleted Both indicators will go off to indicate the battery is depleted and the unit is totally unpowered The battery will last 5 years in normal use provided it is not exposed to extremes of temperature for prolonged periods or fully discharged charged a large number of times We recommend that the functioning of the rechargeable battery is checked at least yearly as follows 4 2...

Страница 7: ... is fully connected and that the connection is not damaged If the amber fault indicator flashes check that the battery is connected 6 Limitations of Radio Communications Ei Electronics radio communication systems are very reliable and are tested to high standards However due to their low transmitting power and limited range required by regulatory bodies there are some limitations to be considered ...

Страница 8: ...rkmanship If this device should become defective within the guarantee period we shall at our discretion repair or replace the faulty unit This guarantee only applies to normal conditions of use and service and does not include damage resulting from accident neglect misuse unauthorised dismantling or contamination howsoever caused This guarantee excludes incidental and consequential damage Do not i...

Страница 9: ...9 Template for Mounting Screws Drill Holes Here 12V 180mA max Aux1 12V 20mA max Aux2 Remove protection plug before connecting accessories Vibration Pad Ei170RF Conversion Jack Ei171RF Figure 5 ...

Страница 10: ...5 sec 1 flash 5 sec 1 flash 5 sec 1 flash 5 sec off off off off off off off off Mains off battery connected Mains off battery virtually depleted Mains off battery fully depleted In Alarm Activated by an Alarm RF signal Test Mode Test button pressed 1 flash 2 sec 40 flashes min on for 4 sec on for 4 sec 2 sec on off pulse on 1 flash 2 sec Test button pressed on RF Alarm Fault Mode Vibration Pad dis...

Страница 11: ...11 Mains Indicator Green mains disconnected amber flash 4 seconds RadioLINK Indicator Blue Control Panel Indicators Alarm Indicator Red Fault Indicator Amber Strobe TEST ALARM FAULT Indicator Summary ...

Страница 12: ...ible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and proper disposal please contact your local government office or the retailer where you purchased this product Block E1 Hereby Ei Electronics declares that this Ei170RF Ei171R...

Отзывы: