If you installed Smoke Alarms with RadioLINK modules and did not House Code
them, you may be receiving alarm signals from a neighbouring system. This can be
HDV\UHFWLILHGE\´+RXVH&RGLQJµ\RXU$ODUPVVHHWKH¶5DGLR/,1.0RGXOH%RRNOHW·
1. To cancel a false alarm from a Smoke Alarm (which has its red light flashing
rapidly), press the Test/Hush button.
The Smoke Alarms will be silenced for a period of approximately 10 minutes. The
red light on the cover of the Smoke Alarm will flash every 8 seconds to indicate that
the alarm has been silenced.
2. The Smoke Alarm will reset at the end of the silenced period (10 minutes).
3. If kitchen usage/layout is such that there are an unacceptable level of nuisance
alarms, re-locate the Smoke Alarm further away where it will be less affected by
cooking fumes etc. We recommend the use of a Heat Alarm in the Kitchen area to
avoid such nuisance alarms.
5.3 Power Supply Monitoring
5.3.1 What to do when an Alarm is beeping/flashing:
a)
If a Smoke Alarm is beeping about every 32 seconds with the red light flashing
at the same time:
7KLVLQGLFDWHVWKDWWKH/LWKLXP%DWWHU\LVSDUWLDOO\GHSOHWHGDQGWKH6PRNH$ODUP
needs to be replaced. (check the “replace by” date marked on the side of the
Alarm).
b)
On Smoke Alarm models with RadioLINK modules (fitted) - If the green light
flashes every 10 seconds it indicates that the RadioLINK battery is depleted and
the RadioLINK module must be replaced.
20