20
and holding the House Code switch on for about 6 seconds
until the amber light comes on and then flashes slowly.
Repeater Function: The smoke alarm receives and then
re-broadcasts the varoius RF signals, so effectively boosting
the signal range. Should be used with three or more
RadioLINK units. You can only have one repeater per system.
Activating the Repeater Function: Press and hold the test
button until the alarm sounds and the amber light comes on,
then immediately (while the light is on) press and hold the
House Code switch until the amber light flashes slowly. The
amber light will flash 15 times to indicate that smoke alarm is
now a Repeater unit.
De-activating the Repeater Function: Press and hold the
test button until the alarm sounds and the amber light comes
on, then immediately (while the light is on) press and hold the
House Code switch until the amber light flashes slowly. The
amber light will now flash only 3 times to indicate that the
smoke alarm is now no longer a Repeater unit.
Ei Electronics. Shannon, Co. Clare, Ireland.
Tel: (061) 471277 Fax: (061) 471053
E-mail. [email protected]
visit us at: www.eielectronics.com
Ei Electronics, Shannon, Co. Clare, Ireland
Nominal activation conditions/ sensitivity,
response delay (response time) and
performance under fire condition
Pass
Operational reliability
Pass
Tolerance to voltage supply
Pass
Response delay and temperature resistance
Pass
Vibration resistance
Pass
Humidity resistance
Pass
Corrosion resistance
Pass
Electrical stability
The Declaration of Performance No. 13-0001 may be consulted
at www.eielectronics.com/compliance
Pass
08
DoP No.13-0001
EN14604:2005 + AC:2008
Smoke Alarm Devices:
Ei3100RF, Ei3500RF, Ei3105RF
Fire Safety
0086
Hereby, Ei Electronics declares that these Ei3100RF, Ei3500RF, Ei3105RF Alarms
are in compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC. The Declaration of Conformity may be consulted
at www.eielectronics.com/compliance