background image

(3)

These appliances must “breathe in” air to burn the fuel properly. Know where the
air comes from and ensure vents/air bricks etc. remain unobstructed
(particularly after building work).

(4)

The appliances must also “breathe out” the waste gases (including the CO) –
usually through a flue or chimney. Ensure chimneys and flues are not blocked or
leaking, and get them checked every year. Check for excessive rust or cracks on
appliances and pipe work.

(5)

Never leave your car, motor bike or lawnmower engine running in the garage
with the garage door closed. Never leave the door from the house to the garage
open if the car is running.

(6)

Never adjust your own gas pilot lights.

(7)

Never use a gas cooker or a barbecue for home heating.

(8)

Children should be warned of the dangers of CO poisoning and instructed never to
touch, or interfere with the CO Alarm. Do not allow small children to press the
test/hush button as they could be subjected to excessive noise when the unit alarms.

(9)

Leaving windows or doors slightly open (even a few inches) will significantly reduce
the risk of high levels of CO occurring. The high levels of draught-proofing in
modern houses reduces ventilation and can allow dangerous gases to build up.

(10)

Install CO Alarms in all the areas recommended in this leaflet.

(11)

Recognise that CO poisoning may be the cause when family members suffer from
“flu-like” symptoms when at home but feel better when they are away for extended
periods.

25

B15583-R3-203-204-205 U&C  8/5/04  7:45 AM  Page 25

Содержание Ei 204EN

Страница 1: ...ling the unit the leaflet must be given to the householder The leaflet is to be given to any subsequent user BATTERY POWERED CARBON MONOXIDE ALARM INSTRUCTIONS Model Ei 203EN Basic Model Ei 204EN Stan...

Страница 2: ...HE SILENT KILLER WHERE TO PLACE CARBON MONOXIDE ALARMS INSTALLATION TESTING MONITORINGYOUR CO ALARM MAINTENANCE LIMITATIONS OF CARBON MONOXIDE ALARMS HOW TO PROTECTYOUR FAMILY TECHNICAL SPECIFICATIONS...

Страница 3: ...time e g bedrooms kitchens and sitting rooms In rooms with an appliance install preferably on the ceiling 300mm from walls and between 1m to 3m horizontally from appliance In rooms remote from the ap...

Страница 4: ...d flues clear and in good condition and all of your appliances serviced regularly according to the manufacturer s instructions Do not fit alarm until all building work is completed to avoid contaminat...

Страница 5: ...ecoming the owner of an Ei Carbon Monoxide Alarm This will help protect you and your household from the dangerous effects of Carbon Monoxide the silent killer CO is the chemical symbol indicating the...

Страница 6: ...o important The following symptoms are related to Carbon Monoxide poisoning and should be discussed with all members of the household Mild Exposure Slight headache nausea vomiting fatigue often descri...

Страница 7: ...l headaches within 1 2 hours life threatening after 3 hours also maximum parts per million in flue gas on an air free basis according to US Environmental Protection Agency 800 Dizziness nausea and con...

Страница 8: ...ess it has been in alarm see CO Alarm Memory below If your CO Alarm sounds follow the instructions on page 4 When ventilation is provided by leaving the window and doors open the CO build up may have...

Страница 9: ...Alarm may sound if cigarette smoke is blown into it or aerosols are released nearby CO ALARM MEMORY Ei205EN Ei205ENA Ei205CEN only Red light is Off No CO detected since reset or power up Red light fl...

Страница 10: ...limited the following points should be considered when deciding where best to fit the alarm s If there is an appliance in a room where people sleep place a CO Alarm in this room and Locate a CO alarm...

Страница 11: ...fected by draughts 7 Next to an extractor fan 8 Where it would be obstructed e g by curtains or furniture 9 In an area where the temperature could drop below 10 C or rise above 40 C 10 Where dirt or d...

Страница 12: ...potential CO source If there is a partition in the room the CO alarm should be located on the same side of the partition as the potential source In rooms with sloped ceilings the CO alarm should be l...

Страница 13: ...13 300mm 150mm 1 to 3 m 1 to 3 m DEAD AIR DON T LOCATE HERE CO Alarm Figure 2 Location in room with a fuel burning appliance B15583 R3 203 204 205 U C 8 5 04 7 45 AM Page 13...

Страница 14: ...in bedrooms other rooms remote from the appliance i e at breathing level 300mm CO Alarm Figure 3 Location in rooms with sloped ceilings the CO alarm should be located at the high side of the room B155...

Страница 15: ...green red amber lights will immediately flash in sequence to show they are working this is normal Once you have selected a suitable location open the battery compartment by sliding up the cover as sho...

Страница 16: ...pack as follows i Remove the battery cover as shown in figure 5a ii Remove the post shown in figure 6 Place it on the corner of a table and push downwards note cover unit with a cloth to prevent the p...

Страница 17: ...sing the toxic gas flashes its red light Low polarised cable is suitable as the alarms are battery powered Up to 250 metre 820 ft of wire can be used provided the maximum resistance between any alarm...

Страница 18: ...e alarms similarly ensuring the terminals marked 1 are all connected together and that the terminals marked 2 are all connected together 6 After installation press each test button for at least 15 sec...

Страница 19: ...Indicator If the unit beeps and the green light flashes simultaneously every 45 seconds then the three batteries are depleted Check the Replace by label on the side wall if it has been exceeded repla...

Страница 20: ...in the event of problems Check the pull tag has been removed to connect the batteries Check there are three batteries installed with the correct orientation in the battery compartment If the batterie...

Страница 21: ...Do not use any cleaning agents bleaches detergents or polishes including those in aerosol cans Avoid spraying air fresheners hair spray paint or other aerosols near the CO Alarm Do not place air fres...

Страница 22: ...e CO Alarm will not work without good batteries the green power light must flash every 45 seconds If the battery has been drained the alarm will not give protection Button test the alarm on return fro...

Страница 23: ...years operation 5 CO Alarms are not a substitute for life insurance House holders are responsible for their own insurance The CO Alarm warns of increasing CO levels but we do not guarantee that this...

Страница 24: ...arbon Monoxide may be present These include The CO Alarm warning of abnormal levels Staining sooting or discolouration on or around appliances A pilot light frequently going out A strange smell when a...

Страница 25: ...as pilot lights 7 Never use a gas cooker or a barbecue for home heating 8 Children should be warned of the dangers of CO poisoning and instructed never to touch or interfere with the CO Alarm Do not a...

Страница 26: ...the red light and the horn will turn on again after about 4 minutes The unit can only be silenced once during a CO incident At 300 ppm CO the unit cannot be silenced With interconnected units the hus...

Страница 27: ...ed light for 2 seconds every 40 seconds Ei205CEN only 2 flashes for 50 ppm CO 4 flashes for 100 ppm CO and 8 flashes for 300 ppm CO When the test button is pressed the red light flashes as per table B...

Страница 28: ...N excluding replaceable batteries for one year from date of purchase against any defects that are due to faulty materials or workmanship Ei Electronics guarantees Carbon Monoxide Alarms Models Ei204EN...

Страница 29: ...LARM BEEPS EVERY 45 SECONDS If the Alarm beeps every 45 seconds and green light flashes at the same time then the unit must be replaced if the Replace by date on the side wall has been exceeded If it...

Страница 30: ...boats or in UPS s Uninterruptible Power Supplies 5 Ensure there is not excessive smoke or fumes from devices such as Egyptian shisha hookah or hubbly bubbly pipes especially those that use coal or cha...

Страница 31: ...sible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For mor...

Страница 32: ...es eielectronics ie www eielectronics com Aico Ltd Mile End Business Park Maesbury Rd Oswestry Shropshire SY10 8NN U K Tel 0870 7584000 Fax 0870 7584010 E mail support aico co uk www aico co uk Ei Ele...

Отзывы: